12
OPERATING INSTRUCTIONS
Figure 3
Control Panel
Open Door
If the door is opened, while the unit is operating, it must be
closed within 30 seconds or the unit will go into vacuum
error mode. If this happens, close the door, turn the control
panel switch to "OFF" then back to the setting it was
previously at.
Refueling
For maximum performance we recommend that you do not
let the hopper drop below 1/4 full. KEEP LID CLOSED
AT ALL TIMES EXCEPT WHEN REFILLING. DO
NOT OVERFILL HOPPER.
Safety Features
1.
Your unit is equipped with a "high temperature
limit" thermo snap disc. This snap disc serves to
shutdown the auger in the case of an over
temperature situation (such as convection fan
failure). This disc has a manual reset button that
will have to be reactivated once the unit has cooled
down.
2.
If the combustion fan malfunctions a vacuum
switch will automatically shut down the auger (see
also Open Door section above).
If either of these situations occur contact your dealer as a service call may be
required.