Installing the Exhaust System
3.1 Before You Begin
For efficient and safe operation of The WaterHeater™ by ITR
follow all recommendations for properly installing the exhaust.
Any deviations from these must be approved in advance by ITR.
Although the heater’s exhaust produces very low carbon
monoxide emissions, caution is still advised:
Section
3
!
DANGER
•
Do not operate The WaterHeater™ by ITR in an enclosed
area unless there is adequate ventilation.
•
Isolate The WaterHeater™ by ITR in a closed compartment
so that no air from the unit will infiltrate the living areas.
Never place any exhaust parts close to combustible material or
through a combustible wall or ceiling without fireproof protection.
The exhaust can reach high temperatures.
3.2 Mounting
Location
If you can’t meet the technical specifications for mounting
the exhaust, don’t use The WaterHeater™ by ITR. The unit
may perform poorly or become damaged if not installed
according to specifications.
Recommended Exhaust Outlet Locations
The following is recommended for a coach exhaust outlet
location:
•
Mount the exhaust outlet outside the coach, not inside
the heater compartment. Otherwise, exhaust fumes could
infiltrate the coach from The WaterHeater™ by ITR
compartment.
International Thermal Research
3-1