Section 6, Wiring the Electrical System
6.3 120
VAC
•
The WaterHeater™ by ITR is equipped with one 1500 watt
120 VAC electrical element. The connections for the electrical
supply are on the top left side of The WaterHeater™ by ITR,
under a cover, labeled AC power.
•
The power wires for the AC elements are three 14 gauge
stranded copper leads that use standard AC color code
(black - hot, white – neutral, green - ground). These are to
be connected using standard 120 VAC electrical connectors
and terminals. Once the connection is completed, the wires
are to be inserted back into their compartment and the cover
secured.
Do not operate the electric elements until water is added to The
WaterHeater™ by ITR and Space Heating Module (optional) and all
trapped air has been removed.
NOTICE
6.4 Remote Operating Panel Cable
•
The other connection on the top right of The WaterHeater™
by ITR is a short four (4) wire remote operating panel cable
with a four (4) pin connector. This connects to a matching
25’ connector cord that plugs directly into the Remote
Operating Panel. Refer to Figure 6-1: System Wiring.
6-2 The WaterHeater™ by ITR