Section 8, Operating the WaterHeater
8-10
The WaterHeater™ by ITR
•
Regular inspection and maintenance are a necessary part of a
properly operating module and satisfactory performance.
8.9 Protect the WaterHeater™ and Space
Heating
Module
(If
Installed)
•
Protect The WaterHeater™ by ITR and Space Heating Module
from temperature extremes and any dusty, dirty, corrosive
environment.
•
Protect The WaterHeater™ by ITR and Space Heating Module
from cold temperatures and corrosion. Protect the Space
Heating Module coolant side by using a proper mixture of
anti-freeze and water. Use only a non-toxic propylene glycol
based coolant with additives generally recognized as safe
“GRAS” by the FDA in the coolant side of the Space Heating
Module. Read and follow the anti-freeze manufacturer’s
instructions for the type of anti-freeze and mixture
recommended for your application.
•
Note that any domestic water in The WaterHeater™ by ITR or
Space Heating Module will freeze in cold temperatures and
will damage the components. The WaterHeater™ by ITR and
Space Heating Module and all associated components must be
completely drained of the domestic water and emptied before
freezing temperatures are encountered.
8.10 General
Troubleshooting
Insure that The WaterHeater™ by ITR has both sufficient
battery voltage and water level as The WaterHeater™ is
designed not to allow operation if either are incorrect
(indicated by lit Voltage Fault or Low Water Level Fault
LED’s on The WaterHeater™ Control Panel) .
Burner Does Not Start Up
•
WaterHeater™ connected to 12 VDC power?
•
Power On/Off button on WaterHeater™ Control Panel pushed
ON? Power LED lit on Remote Operating Panel?
•
Burner switch on Remote Operating Panel ON?
•
Fuses or circuit breakers blown or tripped?