44
TruVision IP Compact PTZ Camera Configuration Manual
•
Invalid Login
: Wrong user ID or password used to login to the cameras.
To define exception alarms:
1. From the menu toolbar, click
Camera Configuration
>
Alarm/Event Setup
>
Exception
.
2. Under
Notification Type
, select one of the exception alarms from the drop-down
list. The options are: HDD Full, HDD error, Network Disconnected, IP Address
Conflicted, Invalid Login.
3. Select the desired the actions: Notify Surveillance Center, Send email, or Trigger
Alarm Output. If “Trigger Alarm Output” is selected, select which type is required:
Select Trigger Alarm Output, A->1, or A->2.
4. Repeat steps 2 and 3 for each of the exception type alarms to be configured.
5. Click
Save
to save changes.
Audio exception detection
Audio exception detection detects sounds that are above a defined threshold.
To set up audio exception detection:
1. From the menu toolbar, click
Camera Configuration
>
Alarm/Event Setup
>
Audio Exception Detection
.
Содержание TruVision TVP-5101
Страница 1: ...TruVision IP Compact PTZ Camera Configuration Manual P N 1073407 EN REV B ISS 23MAY18 ...
Страница 79: ......