2. Safety
2.1 Safety Signal Words
DANGER
Indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury. This
signal word is limited to the most extreme situations.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
NOTICE
Indicates that equipment or property damage can result if
instructions are not followed.
SAFETY
INSTRUCTIONS
Safety instructions (or equivalent) signs indicate
specific safety-related instructions or procedures.
Note:
Contains additional information important to a
procedure.
2.2 Installation Warnings
WARNING
DO NOT use this water heater for any purpose other
than water heating.
Read, understand, and follow the Installation and Operation
manuals, including all warnings and precautions, before
operating this water heater. If you do not follow these
instructions exactly, a fire or explosion may result, causing
property damage, personal injury, or loss of life.
Follow all local codes and the most recent edition of the
National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA
or the Natural Gas and Propane Installation Code in Canada
(CSA B149.1).
This water heater must be installed by a licensed plumber,
gas fitter, and/or professional service technician. Installation
by unqualified person(s) voids the warranty.
Designed for operations at outlet temperature(s) not in
excess of 190°F (88°C).
DANGER
A. This water heater does not have a pilot. It is equipped
with an ignition device which automatically lights the
burner. Do not try to light the burner manually.
B.
BEFORE OPERATING, smell all around the water
heater area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire or
police department.
C. Use only your hand to turn the manual gas shut-off
valve. Never use tools. If manual gas shut-off valve will
not turn by hand, don’t try to repair it. Call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
WARNING
DO NOT use or store flammable liquids around the water
heater, including gasoline, oils, spray paints, etc.
DO NOT operate this water heater unless it is properly
vented to the outside (the exhaust vent piping must be
connected from the unit directly to the outside). Improper
venting can cause a build-up of carbon monoxide, which
can result in brain damage or death. Exhaust gases must
be completely expelled out of the building.
This water heater is factory preset for NATURAL GAS
but may be field converted for use with propane.
For propane conversion, refer to the Propane (LPG)
Conversion section of this manual. Connecting the
water heater to any other gas supply can result in
property damage, serious injury, or even death.
This water heater is suitable for use in potable water
heating applications. The cold and hot water fittings on
the top of the water heater MUST NOT be connected to
any heating system.
The water heater temperature is factory set to 120°F
(49°C). Hot water temperatures above 125°F can cause
severe burns instantly or death from scalds. If the
proposed water heater outlet temperature is to be set
above 125°F, installation of a thermostatically controlled
(or temperature limiting) mixing valve is recommended
for all hot water going to faucets to avoid the risk
of scalding. Examples include commercial applications
where 140°F (60°C) is often needed or if the space
heating temperature required is higher than the domestic
hot water. Always check the temperature of the hot
water before bathing, showering, washing, etc.
Protect against snow and debris accumulation around
the vent terminations. Regularly inspect the exhaust
vent pipe and the air intake pipe to ensure they remain
clear from obstructions at all times.
Содержание iN401
Страница 4: ......
Страница 44: ...iN401 iN501 Operation 40 May 2019 Revision 00 12 5 2 Changing Passcode ...
Страница 76: ...iN401 iN501 Product Warranty 72 May 2019 Revision 00 This page has been intentionally left blank ...
Страница 77: ...iN401 iN501 May 2019 Revision 00 NOTES ...
Страница 78: ...iN401 iN501 74 May 2019 Revision 00 NOTES ...
Страница 79: ...Endless water Zero waste ...