7. Air Intake Inlet and Exhaust Gas Outlet Pipe Connections
DANGER
Improper venting of the water heater will result in
excessive levels of carbon monoxide, which can lead to
severe personal injury or death. This water heater must
be vented in accordance with the “Venting of Equipment”
section of the latest edition of the ANSI Z223.1 / NFPA
54 (Natural Fuel Gas Code) in the USA, or in Canada
refer to the “Venting Systems and Air Supply for
Appliances” section in the latest version of CAN/CGA
B149.1 (Natural Gas and Propane Installation Code), and
all applicable local building codes. Vent installation
should be performed only by a licensed professional.
WARNING
Do not operate flood damaged water heaters.
Install venting system according to the
required codes and material manufacturers
specifications.
Do not obstruct fresh air intakes or exhaust
outlets. Adequately support all vent system
piping.
Do not place vapor emitting products near
water heater or air intake.
Place working carbon monoxide detectors
outside each sleeping area.
Do not operate the water heater before
properly installing the exhaust outlet.
Visually inspect the vent system and
eliminate any possible area where
condensation could create a blockage of
intake or exhaust air.
Breathing concentrated levels of carbon
monoxide, even for a short period of time, will
cause brain damage and can even lead to
death.
BREATHING HAZARD
CARBON MONOXIDE GAS
•
•
•
•
•
•
•
Note:
This water heater falls into the Category IV appliance.
7.1 Quick Reference Installation Guide
1. Select the desired type of venting system: Two Pipe Vent
System (Direct) or Single Pipe Vent System (Power).
“7.3 Two Pipe Vent System (Direct Vent)” on page 20.
“7.4 Single Pipe Venting System (Power Vent)” on page
22.
2. Select the desired termination of the air intake inlet and
exhaust gas outlet pipe; outside wall or roof.
“7.3.3 Side Wall Air Intake Inlet and Exhaust Gas Outlet
Pipe Termination” on page 21.
“7.3.4 Roof Air Intake Inlet and Exhaust Gas Outlet Pipe
Termination” on page 22.
3. Determine the straight line distance and the number of
elbows required to route the air intake inlet and exhaust
gas outlet pipes to their termination point.
“7.6 Intake Air Inlet and Exhaust Gas Outlet Pipe
Diameter and Length” on page 24.
4. Determine the diameter of pipe required to properly bring
in intake air and vent exhaust gas.
“7.6 Intake Air Inlet and Exhaust Gas Outlet Pipe
Diameter and Length” on page 24.
5. Verify the location of the air intake inlet and exhaust gas
outlet terminations are within state and local codes.
“7.7 Venting Clearance Specifications” on page 25.
6. Select an approved material for the air intake inlet piping.
“7.8 Exhaust Gas Outlet Pipe Materials” on page 26.
7. Select an approved material for the exhaust gas outlet
piping. “7.9 Air Intake Inlet Pipe Vent Materials” on page
26.
7.2 Typical Single Unit Air Intake Inlet and
Exhaust Gas Outlet Pipe Installation
1. Select one of the two venting configurations: two pipes
(direct vent) configuration or with one pipe (power vent)
configuration.
2. Select the desired termination location and make sure
each pipe terminates within all local and state codes.
3. Select the desired material for the air intake inlet and
exhaust gas outlet pipes.
CAUTION
This water heater has a factory preset control to limit
the exhaust gas temperature to 149°F (65°C) when
the PVC is selected in the “Flue Type” programming
section. As a result, the water heater can be vented
with Schedule 40 PVC. If the incoming (or recirculation
return) water temperature does not exceed 150°F
(66°C), the exhaust gas temperature will not exceed
149°F (65°C).
WARNING
When the unit is set for CPVC (polypropylene pipe),
flue temperatures can reach 190°F (88°C). PVC pipe
will melt at temperatures above 149°F (65°C) and could
therefore result in a fire. Make sure the setting and the
type of material being used for the flue are compatible.
For this application use Schedule 80 CPVC or Approved
Polypropylene in the USA or Type BH Special Gas Vent
Class IIB (CPCV) or Class IC (Polypropylene) that
conforms to ULC-S636 in Canada.
Содержание iN401
Страница 4: ......
Страница 44: ...iN401 iN501 Operation 40 May 2019 Revision 00 12 5 2 Changing Passcode ...
Страница 76: ...iN401 iN501 Product Warranty 72 May 2019 Revision 00 This page has been intentionally left blank ...
Страница 77: ...iN401 iN501 May 2019 Revision 00 NOTES ...
Страница 78: ...iN401 iN501 74 May 2019 Revision 00 NOTES ...
Страница 79: ...Endless water Zero waste ...