MP73P+ : Battery charger/analyser
Operators Manual
(G) - POSITIVE BATTERY TERMINAL
Connection of the positive battery lead is made to this terminal.
(H) - HEAT EXCHANGER EXHAUST FAN
During use the unit absorbs electrical power, which it turns into heat, this fan exit is
where the heat is extracted from the unit. It is important that it is not obstructed.
(I) & (J) - CHARGE & CAPACITY TEST CIRCUIT BREAKERS
The circuit breakers are fitted to prevent high currents from being driven into the
battery or into the unit should a fault condition occur. Always ensure that the circuit
breaker is in the ON position before starting a charge or capacity test.
WARNING
NEVER SWITCH THE CIRCUIT BREAK TO ON WHEN THE UNIT IS PERFORMING A
CHARGE OR CAPACITY TEST AS SEVERE DAMAGE MAY OCCUR TO THE BATTERY OR THE
EQUIPMENT
ALWAYS PRESS STOP FIRST !
If the circuit breaker operates during a charge immediately press STOP and remove
power from the unit and disconnect the battery.
Operation of the circuit breaker is an indication of a fault and the unit will need to be
checked before using.