background image

Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS                                Appendix A: Product Usage Tips 

79 

Intel Confidential 

Revision 1.2 

 

Intel order number E69391-006

 

Appendix A: Product Usage Tips 

ƒ

 

When adding or removing components or peripherals from the server board, AC power 
must be removed. With AC power plugged into the server board, 5-Volt standby is still 
present even though the server board is powered off. 

ƒ

 

Each time AC power is applied to the server, the Blue System ID LED will turn on, the 
power button will be disabled, and a delay of 30-45 seconds will occur before the system 
is able to power on. This delay is needed to reset the BMC controller on the BMC 
Management Module. Once the BMC reset has completed, the System ID LED will turn 
off, and the power button will be re-enabled allowing for the system to be powered on.

 

ƒ

 

Only the Intel

®

 Xeon

®

 Processor 5500 Series and 5600 Series with 

130 Watt

 and less 

Thermal Design Power (TDP) are supported on the 

Intel

®

 Server Board S5500HV

Previous generations of the Intel

®

 Xeon

®

 processors are not supported.  

ƒ

 

Only the Intel

®

 Xeon

®

 Processor 5500 Series and 5600 Series with 

95 Watt

 and less 

Thermal Design Power (TDP) are supported in the 

Intel

®

 Server System SR1670HV

Previous generations of the Intel

®

 Xeon

®

 processors are not supported. 

ƒ

 

Only registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs (UDIMMs) are 
supported on this server board. Mixing of RDIMMs and UDIMMs is not supported. 

ƒ

 

For the best performance, the number of DDR3 DIMMs installed should be balanced 
across both processor sockets and memory channels. For example, a two-DIMM 
configuration performs better than a one-DIMM configuration. In a two-DIMM 
configuration, DIMMs should be installed in DIMM sockets A1 and D1. A six-DIMM 
configuration (DIMM sockets A1, B1, C1, D1, E1, and F1) performs better than a three-
DIMM configuration (DIMM sockets A1, B1, and C1). 

ƒ

 

Due to thermal requirements needed to support Quad Rank x4 DDR3 DIMMs, this 
memory type is not supported in the 

Intel

®

 Server System SR1670HV

. Support for this 

memory type should be verified with other server chassis/system manufacturers 
planning to support this server board. 

ƒ

 

Memory is only populated using DIMM slots associated with a given installed processor. 
Ie.) With only one processor installed, only the DIMM slots associated with that 
processor should be populated. Memory installed into DIMM slots for a processor that is 
not installed are non-functional. 

ƒ

 

The Management NIC port is only enabled with the BMC Module installed on to the 
server board. With no BMC module installed, the Management NIC port, located above 
the rear external USB ports, will be non-functional. 

ƒ

 

Reference the Intel

®

 Server System SR1670HV Service Guide for RAID setup 

information 

ƒ

 

Reference the Intel

®

 Server System SR1670HV Service Guide for BIOS setup 

information 

ƒ

 

Reference the Intel

®

 Server System SR1670HV Service Guide for System Update Utility 

usage information 

ƒ

 

Reference the Intel

®

 Server System SR1670HV Service Guide for system service and 

support information 

.

Содержание SR1670HV - Server System - 0 MB RAM

Страница 1: ...Intel Server Board S5500HV Intel Server System SR1670HV Technical Product Specification Intel order number E69391 006 Revision 1 2 May 2010 Enterprise Platforms and Services Division...

Страница 2: ...or characteristics of any features or instructions marked reserved or undefined Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibiliti...

Страница 3: ...ocessor Population Rules 11 3 1 3 Unified Retention System Support 11 3 2 Intel QuickPath Memory Controller and Memory Subsystem 12 3 2 1 Intel Server Board S5500HV Memory Support 13 3 3 Intel 5500 Ch...

Страница 4: ...sable Jumper 44 6 4 Embedded RAID Option Select Jumper 45 6 5 DDR3 voltage control jumpers Future Support Only 46 6 6 BIOS Recovery Jumper 47 7 Intel Light Guided Diagnostics 48 7 1 Standby Voltage LE...

Страница 5: ...ompatibility 63 10 1 6 BSMI Taiwan 64 10 1 7 RRL Korea 64 10 2 Intel Server System SR1670HV Regulatory and Certification 64 10 2 1 Product Regulatory Compliance 64 10 2 2 Use of Specified Regulated Co...

Страница 6: ...Figure 13 NIC Enable Disabled Jumper Block 22 Figure 14 Video Enable Disable Jumper Block 23 Figure 15 Baseboard Management Module 24 Figure 16 Management NIC 25 Figure 17 System Fan Connector Locati...

Страница 7: ...r System SR1670HV Back Panel Overview 52 Figure 38 Intel Server System SR1670HV Front Control Panel LEDs 53 Figure 39 LAN Port LED Identification 53 Figure 40 Hard Drive LED Identification 54 Figure 4...

Страница 8: ...13 FRU Sensors 31 Table 14 BIOS Error Messages and Checkpoints 31 Table 15 VGA Connector Pin out 40 Table 16 RJ 45 10 100 1000 NIC Connector Pin out 41 Table 17 Serial Port Pin out 41 Table 18 Externa...

Страница 9: ...Intel Server Board S5500HV Intel Server System SR1670HV TPS List of Tables Revision 1 2 Intel Confidential ix Intel order number E69391 006 This page intentionally left blank...

Страница 10: ...m SR1670HV Overview Chapter 9 Environmental Specifications Chapter 10 Regulatory and Certification Chapter 11 Product Safety Information Appendix A Product Usage Tips Glossary of Terms Product Referen...

Страница 11: ...O Control External connections DB 15 Video connector DB 9 COM1 Serial Port connector Two RJ 45 Network Interface Connectors Stacked for 10 100 1000 Mb One RJ 45 Management Network Interface Connector...

Страница 12: ...verview 3 Intel Confidential Revision 1 2 Intel order number E69391 006 Feature Description Server Management On board ASPEED AST2050 with integrated Baseboard Management Controller BMC Management Mod...

Страница 13: ...Overview Intel Server Board S5500HV Intel Server System SR1670HV TPS Revision 1 2 Intel Confidential 4 Intel order number E69391 006 2 2 Server Board Layout Figure 1 Intel Server Board S5500HV...

Страница 14: ...umber E69391 006 2 2 1 Server Board Connector and Component Layout The following figure shows the board layout of the server board Each connector and major component is identified by letter with a des...

Страница 15: ...y E CPU 2 DIMM Slots Slots D1 F2 O Auxilary Front Panel Header F CPU 1 LGA 1366 Socket P Front Panel Header G Power Supply SMBus 2x3 Pin Header Q X16 GEN 2 PCI Express Riser Card Slot H Main Power Con...

Страница 16: ...evel description of the functionality associated with each chipset component and the architectural blocks that make up the server board Figure 4 Intel Server Board S5500HV Functional Block Diagram 3 1...

Страница 17: ...l QuickPath Technology Hyper threading Intelligent power Turbo boost Integrated Memory Controller The processor supports all the existing Streaming SIMD Extensions 2 SSE2 Streaming SIMD Extensions 3 S...

Страница 18: ...data 256KB per core Performance Very low latency new dedicated L2 cache improves performance by reducing latency to frequently used data Scalability As core count increases pressure on shared cache is...

Страница 19: ...rd supports full width communication only 3 1 1 3 Intel Hyper Threading Technology Intel Hyper Threading Technology lets you run two threads at the same time per core This capability lets the processo...

Страница 20: ...SR dual rank DR and quad rank QR Registered DIMM RDIMM or Unbuffered DIMM UDIMM 3 1 2 Processor Population Rules Note Although the server board does support dual processor configurations consisting o...

Страница 21: ...ee the following figure for the stacking order of the URS components AF002699 Heatsink Screw Compression Spring Retention Cup Thermal Interface Material TIM Retaining Ring Server Board Heatsink Attach...

Страница 22: ...The following table shows the maximum memory amounts possible using RDIMM type memory Single Rank RDIMMs 800 MHz and 1066 MHz 48 GB 12x 4GB DIMMs Dual Rank RDIMMs 800 MHz and 1066 MHz 96 GB 12x 8GB D...

Страница 23: ...w Figure 9 Intel Server Board S5500HV Memory Slot Layout Note Memory is only populated using DIMM slots associated with a given installed processor Ie With only one processor installed only the DIMM s...

Страница 24: ...the number of DIMMs installed and rank type When installing memory consider the following Populate DIMMs by channel starting with the Blue slot farthest from the CPU All channels in a system will run...

Страница 25: ...DRAM Density 256 Mb 512 Mb and 4 Gb DRAM technologies x4 DRAM on UDIMM and Quad rank UDIMM are not supported Mixing ECC and non ECC UDIMMs anywhere on the platform will force system to run in non ECC...

Страница 26: ...annel Mode Mirrored Channel Mode Mirrored Channel Mode requires that all installed DIMMs support ECC and that there be matching DIMM populations between channels Matching DIMMs must meet the following...

Страница 27: ...lly DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 1 must be populated the same For example DIMM slots A1 and B1 must h...

Страница 28: ...l QPI interfaces One X16 PCI Express Gen 2 port supporting a single PCI Express Gen2 compliant X16 riser card slot Compliant to the PCI Express Base Specification Revision 2 0 One X4 ESI link interfac...

Страница 29: ...with support for RAID levels 0 1 5 and 10 Windows support only LSI MegaRAID Default with support for RAID levels 0 1 and 10 Windows and Linux By default the server board is configured to support the...

Страница 30: ...tem BIOS recognizes USB specification compliant keyboard and mice 3 5 Network Interface Controller NIC This server board supports two external Gigabit Ethernet ports in a stacked housing on the back e...

Страница 31: ...table provides an overview of the LEDs Table 7 NIC Status LEDs Act Link LED Speed LED Status Description Status Description OFF No Link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection...

Страница 32: ...g video resolutions up to and including 1600x1200 60Hz 16bpp The video is accessed using a standard 15 pin VGA connector found on the back edge of the server board The on board video controller can be...

Страница 33: ...agement Module Additional features of the BMC Module include the following IPMI 2 0 Advanced Encryption Standard AES support Secure Socket Layer SSL support Dynamic Host Configuration Protocol DHCP su...

Страница 34: ...anagement NIC The server board provides Serial Over LAN support via a dedicated 10 100 Mbps Management NIC The management port is located on the back edge of the server board in a stacked housing over...

Страница 35: ...nts provide several platform management features including Note The following feature list is only supported with the BMC Module installed In band Out of Band Sensor monitoring PMBus support PSMI supp...

Страница 36: ...wo fan speed options Full Speed Mode High Density Mode In Full Speed Mode system fans will only operate at highest fan speed providing maximum air flow In High Density Mode fan speed is controlled all...

Страница 37: ...Event Reading Type values are from the Event Reading Type Code Ranges and Generic Event Reading Type Codes tables in the IPMI specification Digital sensors are a specific type of discrete sensor whic...

Страница 38: ...h UC UNC UC cch TR1 Temperature Temperature 01h Threshold 01h UC UNC UC cdh TR2 Temperature Temperature 01h Threshold 01h UC UNC UC 34h VCORE1 Voltage 02h Threshold 01h UC UNC LC LNC UC LC 35h VCORE2...

Страница 39: ...h Backplane1 HD3 Drive Slot 0Dh Discrete 6Fh 01h Drive Presence 02h Drive Fault 6Bh Backplane1 HD4 Drive Slot 0Dh Discrete 6Fh 01h Drive Presence 02h Drive Fault Table 11 Power Module Sensors Power Mo...

Страница 40: ...e DIMM slots associated with CPU 1 Invalid Memory Configuration on CPU2 When CPU2 is not installed this message will occur when DIMMs are populated in any of the DIMM slots associated with CPU 2 Parit...

Страница 41: ...ce conflict when configured by BIOS POST PCI ROM Conflict A PCI adapter generated an I O resource conflict when configured by BIOS POST PCI IRQ Conflict A PCI adapter generated an I O resource conflic...

Страница 42: ...r in the super IO DMA controller is initialized 8259 interrupt controller is initialized L1 cache is enabled E9 Set up floppy controller and data Attempt to read from floppy EA Enable ATAPI hardware A...

Страница 43: ...chipset registers 20 Initialize system management interrupt 24 Uncompress and initialize any platform specific BIOS modules 2A Initializes different devices through DIM 2C Initializes different devic...

Страница 44: ...e system configuration display if needed A4 Initialize runtime language module A7 Displays the system configuration screen if enabled Intialize the CPUs before boot which includes the programming of M...

Страница 45: ...h connectors have identical pin outs and are not used concurrently Figure 19 20 pin ATX Main Power Connector Pin out and Location The server board provides a 4 pin peripheral power connector This conn...

Страница 46: ...ision 1 2 Intel order number E69391 006 Figure 21 SATA Connector Location and Pin out 5 3 Front Panel Headers The server board provides two front panel headers each supporting different platform contr...

Страница 47: ...tivity LED The HDD LED is illuminated each time data is written to or read from one of the attached on board SATA hard disks Power Button Sleep Button 2 pin PWRSW This connector is used to support a f...

Страница 48: ...EDs will illuminate when the System ID Button is pushed 5 System ID Button 2 pin LOCATORBTN These pins can be used to support a front panel System ID Button Pushing this button will change the state o...

Страница 49: ...l Name Description 1 V_IO_R_CONN Red analog color signal R 2 V_IO_G_CONN Green analog color signal G 3 V_IO_B_CONN Blue analog color signal B 4 TP_VID_CONN_B4 No connection 5 GND Ground 6 GND Ground 7...

Страница 50: ...2 NIC_LINKA_100_N LED 13 D3 NIC_ACT_LED_N 14 NIC_LINK_LED_N 15 GND 16 GND 5 5 3 Serial Port Connector The server board provides one external DB9 Serial port with the following pin out Table 17 Serial...

Страница 51: ...line paired with DATAL0 4 GND Ground 5 6 Fan Headers The server board provides four 4 pin system fan connectors capable of supporting fans that meet the following specifications 350mA 740mA 8 88W max...

Страница 52: ...er This jumper allows you to clear the Real Time Clock RTC RAM in CMOS Using this jumper you can clear the CMOS memory of date time and system setup parameters Figure 26 Clear RTC Jumper Block The fol...

Страница 53: ...er block allows you to enable or disable the on board video controller Set to pins 1 2 default to enable video set to pin 2 3 to disable video Figure 27 Video Enable Disable Jumper 6 3 NIC 1 NIC 2 Ena...

Страница 54: ...he server board has the option to select either of two embedded SATA RAID options LSI SATA Software RAID or Intel Matrix Storage Manager By default the jumper block is configured on pins 1 2 to suppor...

Страница 55: ...age level supplied to the DIMM bank and should only be changed when low voltage DDR3 DIMMs are installed Caution Moving these jumpers from their Default position may cause irreparable damage The use o...

Страница 56: ...and all other recovery methods have been exhausted Figure 30 BIOS Recovery Jumper The following files must be located in the root directory of the recovery media 1 xxxxxx ROM 2 AFUDOS EXE Use the foll...

Страница 57: ...at a standby voltage be supplied from the power supply when the rest of the system is powered off To indicate the presence of standby power the server board provides an LED which illuminates as soon a...

Страница 58: ...minates when the System ID button on the front panel is pushed This LED is used to identify the system when servicing is required in a racked environment Figure 33 System ID LED Note The blue system I...

Страница 59: ...ision 1 2 Intel Confidential 50 Intel order number E69391 006 8 Intel Server System SR1670HV Overview The Intel Server System SR1670HV is an integrated 1U rack mount platform utilizing the features an...

Страница 60: ...er node Add in Adapter Support 2 x PCI Express X16 GEN2 slots supporting low profile half height add in cards one per server node Video On board ASPEED AST2050 with integrated Video Controller Integra...

Страница 61: ...gure 36 Intel Server System SR1670HV Front Panel Overview 8 2 Rear Panel Features The server system provides the following features on the system s back panel Dual cold swap 770 Watt Power Supply modu...

Страница 62: ...HDD Message LED OFF Blinking System is normal no incoming event Indicates a HW monitor event System ID LED OFF ON Normal status System ID Button is pressed Press the System ID Button again to turn off...

Страница 63: ...talled hard drive is tray mounted Mounting the hard drive into the tray requires the use of four screws Figure 41 Hard Drive Assembly The hard drive assembly slides into a drive bay where the hard dri...

Страница 64: ...tem provides no redundant fan support To prevent the system from over heating a failed fan should be replaced as soon as possible Figure 44 System Fan Removal Each bank of fans is monitored and contro...

Страница 65: ...power distribution board Each power supply module provides power to a single server node The power supply modules provide no power redundancy Figure 45 Intel Server System SR1670HV Power Sub system Ea...

Страница 66: ...t 12V Fan speed control and Temp Sensors Critical and warning events FRU data Protection Over Current Over Temperature Over Voltage Table 22 Over Current Protection Limits Output Voltage OCP Limits 12...

Страница 67: ...and the PWR LED 8 6 2 AC Power Cord Specification Requirements Table 24 AC Cord Specification Cable Type SJT Wire Size 16 AWG Temperature Rating 105 C Amperage Rating 13 A Voltage Rating 125 V Figure...

Страница 68: ...mperature Disclaimer Note Intel Corporation server boards contain a number of high density VLSI and power delivery components that need adequate airflow to cool Intel ensures through its own chassis d...

Страница 69: ...perating Half sine 2 g peak 11 milliseconds ESD 15 KV except I O port 8 KV per Intel Environmental test specification System Cooling Requirement in BTU Hr 2550 BTU hour Operating Temperature 10 C to 3...

Страница 70: ...ation is obtained Some markings may appear in product literature due to limited space on board for marking Note Certifications Emissions requirements are to Class A Table 28 Server Board Product Safet...

Страница 71: ...1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable prot...

Страница 72: ...o conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions related to...

Страница 73: ...the product safety label which is located on the bottom side pedestal orientation or side rack mount configuration 10 1 7 RRL Korea Following is the RRL certification information for Korea English tr...

Страница 74: ...board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel Representative This is an FCC Class A device...

Страница 75: ...rgentina IRAM Certification Safety CSA 60950 UL 60950 Safety CONFORMS TO ANSI UL STD 60950 1 CERTIFIED TO CAN CSA STD C22 2 No 60950 1 Industry Canada ICES 003 Emissions CANADA ICES 003 CLASS A CANADA...

Страница 76: ...way Hillsboro OR 97124 1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 77: ...conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions related to t...

Страница 78: ...on the product safety label which is located on the bottom side pedestal orientation or side rack mount configuration 10 2 3 7 RRL Korea Following is the RRL certification information for Korea Englis...

Страница 79: ...o be retail product only Marking applied to bulk packaging and single packages Not applied to internal packaging such as plastics foams etc Intel Internal Specification All materials parts and subasse...

Страница 80: ...n Compliance Reference Compliance Reference Marking Example Stand by Power 60950 Safety Requirement Applied to product is stand by power switch is used English This unit has more than one power supply...

Страница 81: ...ognition Canada USA CE DOC Europe CB Certificate Report International Note CB to include all CB national deviations Certification marks to be visible on power supply Power supply is to comply with the...

Страница 82: ...marks to be visible on harness Plastics Requires being UL Recognized and suitable flammability requirement for its application For example Fire Enclosure 18Kg requires min 5V Fire Enclosure 18Kg requ...

Страница 83: ...in noncompliance with product regulations in the region s in which the product is sold 11 1 Safety Warnings Cautions To avoid personal injury or property damage before you begin installing the produc...

Страница 84: ...e all AC power cords are unplugged Make sure the AC power cord s is are unplugged before you open the chassis or add or remove any non hot plug components Do not attempt to modify or use an AC power c...

Страница 85: ...aan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti 11 4 2 Power Cord Warnings If an AC power cord was not provided with your product purchase one that is approved for use in your coun...

Страница 86: ...r supply from the server CAUTION If the server has been running any installed processor s and heat sink s may be hot Unless you are adding or removing a hot plug component allow the system to cool bef...

Страница 87: ...system without the covers in place can damage system parts To install the covers 1 Check first to make sure you have not left loose tools or parts inside the system 2 Check that cables add in boards a...

Страница 88: ...UDIMMs is not supported For the best performance the number of DDR3 DIMMs installed should be balanced across both processor sockets and memory channels For example a two DIMM configuration performs b...

Страница 89: ...bit quantity CBC Chassis Bridge Controller A microcontroller connected to one or more other CBCs together they bridge the IPMB buses of multiple chassis CEK Common Enabling Kit CHAP Challenge Handshak...

Страница 90: ...1024 bytes KCS Keyboard Controller Style KVM Keyboard Video Mouse LAN Local Area Network LCD Liquid Crystal Display LDAP Local Directory Authentication Protocol LED Light Emitting Diode LPC Low Pin C...

Страница 91: ...a Record SECC Single Edge Connector Cartridge SEEPROM Serial Electrically Erasable Programmable Read Only Memory SEL System Event Log SIO Server Input Output SMBUS System Management BUS SMI Server Man...

Страница 92: ...order number E69391 006 Reference Documents Refer to the following documents for additional product information Intel Server System SR1670HV Service Guide Intel Server Board S5500HV Intel Server Syst...

Отзывы: