Connector/Header Locations and Pin-outs
Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS
Revision 1.2
Intel Confidential
42
Intel order number E69391-006
Table 18. External USB Connector Pin-out
Pin
Signal Name
Description
1 USB_OC
USB_PWR
2
USB_PN
DATAL0 (Differential data line paired with DATAH0)
3
USB_PP
DATAH0 (Differential data line paired with DATAL0)
4 GND
Ground
5.6
Fan Headers
The server board provides four 4-pin system fan connectors, capable of supporting fans that
meet the following specifications: 350mA-740mA (8.88W max) or a total of 3.15 A – 6.66 A
(53.28W max) at +12V.
Table 19. 4-pin System Fan Connector Pin-out
Pin
Signal Name
Type
Description
1
Ground
GND
Ground is the power supply ground
2
12 V
Power
Power supply 12 V
3
Fan Tach
In
FAN_TACH signal is connected to the Integrated BMC to monitor the fan
speed
4
Fan PWM
Out
FAN_PWM signal to control fan speed