Server System Overview
Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS
Revision 1.2
Intel Confidential
54
Intel order number E69391-006
8.3.3
Hard Drive Status LEDs
LED
Status
Description
Power
Green Light ON
Red Light ON
G/R Blinking
OFF
Power On (detection HDD present)
RAID HDD fail (HDD plug-in ready but detection error)
RAID rebuilding
HDD not found
Active
Green Blink
Data read/write to HDD
Figure 40. Hard Drive LED Identification
8.4
System Storage
The system can support up to eight 2.5-inch hot-swap SATA/SAS hard drives, four per server
node. Each installed hard drive is tray mounted. Mounting the hard drive into the tray requires
the use of four screws.
Figure 41. Hard Drive Assembly
The hard drive assembly, slides into a drive bay where the hard drive I/O and power connectors
are blind-mated with matching connectors on a backplane.
Hard disk I/O cables from each server node are routed to connectors on the backplane. The
cables can be attached to the SATA ports of each server node (default) or can be attached to
add-in RAID cards. For backplane FRU replacement, the entire hard drive bay is modular and
can be removed from the chassis by removing 6 screws and sliding the entire bay assembly
forward, then up and out of the chassis. See the Intel
®
Server System SR1670HV Service Guide