Platform Management
Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS
Revision 1.2
Intel Confidential
32
Intel order number E69391-006
Message Displayed
Message Description
and Replace
failure.
This message can be reported by an ATAPI device using the SMART error reporting
standard. SMART failure messages may indicate the need to replace the hard disk.
SMART capable and status
BAD
A SMART capable hard disk sends this message when it detects an imminent
failure.
This message can be reported by an ATAPI device using the SMART error reporting
standard. SMART failure messages may indicate the need to replace the hard disk.
System Configuration
DMA-1 Error
Error initializing primary DMA controller. This is a fatal error often indicating a
problem with system hardware
DMA-2 Error
Error initializing primary DMA controller. This is a fatal error often indicating a
problem with system hardware
DMA Controller Error
POST error while trying to initialize the DMA controller. This is a fatal error often
indicating a problem with system hardware
Checking NVRAM… Update
Failed
BIOS could not write to the NVRAM block. This message appears when the FLASH
part is write protected or if there is no FLASH part present.
Unknown CPU is detected,
updating BIOS is required to
unleash its full power!
BIOS could not find or load the CPU microcode update for the CPU detected.
Resource Conflict
More than one system device is trying to use the same non-shareable resources
(memory or I/O)
PCI I/O Conflict
A PCI adapter generated an I/O resource conflict when configured by BIOS POST
PCI ROM Conflict
A PCI adapter generated an I/O resource conflict when configured by BIOS POST
PCI IRQ Conflict
A PCI adapter generated an I/O resource conflict when configured by BIOS POST
Timer Error
Indicates an error while programming the count register of channel 2 of the 8254
timer. This may indicate a problem with system hardware
Interrupt Controller-1 Error
BIOS POST could not initialize the Master Interrupt Controller. This may indicate a
problem with system hardware
Interrupt Controller-2 Error
BIOS POST could not initialize the Slave Interrupt Controller. This may indicate a
problem with system hardware
CMOS
CMOS Date/Time Not Set
The CMOS Date and/or Time are invalid. This error can be resolved by resetting the
system time in BIOS Setup
CMOS Battery Low
CMOS battery is low. This message usually indicates that the CMOS battery needs
to be replaced.
CMOS Settings Wrong
CMOS settings are invalid. This error can be resolved by resetting and saving
options in BIOS setup.
CMOS Checksum Bad
CMOS contents failed the checksum check. Indicates that the CMOS data has been
changed by a program other than the BIOS or that the CMOS is not retaining its
data due to a malfunction. This error can typically be resolved by resetting and
saving options in BIOS Setup.
Miscellaneous
Chassis Intrusion Detected
This message will occur when a chassis intrusion switch has triggered a chassis
intrusion event
Serial Port Component was
not detected
This message will occur when the serial redirection feature is enabled but no serial
port is available.
Boot Block Initialization Code
Checkpoints
D0
1. go to flat mode with 4GB limit and GA20 enabled
2. Initialize CAR function
3. Initialize
CPU