IRET under certain conditions may cause an unexpected Alignment Check
Exception
Problem:
In IA-32e mode, it is possible to get an Alignment Check Exception (#AC) on the IRET instruction
even though alignment checks were disabled at the start of the IRET. This can only occur if the
IRET instruction is returning from CPL3 code to CPL3 code. IRETs from CPL0/1/2 are not
affected. This erratum can occur if the EFLAGS value on the stack has the AC flag set, and the
interrupt handler's stack is misaligned. In IA-32e mode, RSP is aligned to a 16-byte boundary
before pushing the stack frame.
Implication:
In IA-32e mode, under the conditions given above, an IRET can get a #AC even if alignment
checks are disabled at the start of the IRET. This erratum can only be observed with a software
generated stack frame.
Workaround:
Software should not generate misaligned stack frames for use with IRET.
Status:
For the steppings affected, see the
Summary Table of Changes
.
S91
Upper 32 bits of ‘From’ address reported through LBR or LER MSRs, BTMs
or BTSs may be incorrect
Problem:
When a far transfer switches the processor from IA-32e mode to 32-bit mode, the upper 32 bits of
the ‘From’ (source) addresses reported through the LBR (Last Branch Record) or LER (Last
Exception Record) MSRs (Model-Specific Registers), BTMs (Branch Trace Messages) or BTSs
(Branch Trace Stores) may be incorrect.
Implication:
The upper 32 bits of the ‘From’ address debug information reported through LBR or LER MSRs,
BTMs or BTSs may be incorrect.
Workaround:
It is possible for BIOS to contain a workaround for this erratum.
Status:
For the steppings affected, see the
Summary Table of Changes
.
S1S
EXTEST/CLAMP may cause incorrect values to be driven on processor pins
Problem:
When using TAP boundary scan instructions EXTEST/CLAMP while SLP# is asserted at certain
bus ratios, incorrect values may be driven on some processor pins. Address Strobe pins do not
respond at bus ratios 15:1 and 16:1, while Address pins and Request Command pins do not respond
at bus ratio 22:1 and 24:1.
Implication:
Due to this erratum, incorrect values may be driven on some processor pins during boundary scan
testing.
Workaround:
Avoid asserting SLP# when using TAP Boundary Scan instructions EXTEST/CLAMP.
Status:
For the steppings affected, see the
Summary Table of Changes
.
S92
The IA32_MC0_STATUS/ IA32_MC1_STATUS Overflow Bit is not set when
multiple un-correctable machine check errors occur at the same time.
Problem:
When two MC0/MC1 enabled un-correctable machine check errors are detected in the same
internal clock cycle, the highest priority error will be logged in IA32_MC0_STATUS /
IA32_MC1_STATUS register, but the overflow bit may not be set.
Implication:
The highest priority error will be logged and signaled if enabled, but the overflow bit in the
IA32_MC0_STATUS/ IA32_MC1_STATUS register may not be set.
Workaround:
None identified.
Status:
No Fix.