11  Part Disposal

 

Since August 2005 there are EC-wide directives defined in the EC Directive 2002/96/EC and in national 

codes  concerning the waste electrical and electronic equipment and also regarding this device. 
For private households there are special collecting and recycling possibilities. For this device isn’t registered 

for the use in private households, it mustn’t be disposed this way. You can send it back to your national 

sales  organization for disposal. If there are any questions concerning disposal please contact your 

national sales organization. 
Outside the EC, you have to consider the corresponding directives. 

12  Notes and General Information

 

It is important to read this user manual thoroughly and clearly in order to understand the information 

and  instructions. The PolyGard

®

transmitters must be used within product specification capabilities. The 

appropriate operating and maintenance instructions and recommendations must be followed. 
Due to on-going product development, MSR and IN

TEC

 Controls reserve the right to change 

specifications without notice. The  information contained herein is based upon data considered to be 

accurate. However, no guarantee is  expressed or implied regarding the accuracy of this data. 

12.1  Intended Product Application

 

The PolyGard

®

Cl

transmitters are designed and manufactured for control applications and air quality 

compliance in commercial buildings and manufacturing plants. 

12.2  Installers’ Responsibilities

 

It is the installer’s responsibility to ensure that all PolyGard

®

transmitters are installed in compliance with 

all  national and local codes and OSHA requirements. Installation should be implemented only by 

technicians  familiar with proper installation techniques and with codes, standards and proper safety 

procedures for control  installations and the latest edition of the National Electrical Code (ANSI/NFPA70). It 

is also essential to follow  strictly all instructions as provided in the user manual. 

12.3 Maintenance

 

It is recommended to check the PolyGard

®

transmitter regularly. Due to regular maintenance any 

performance  deviations may easily be corrected. Re-calibration and part replacement in the field may be 

implemented by a  qualified technician and with the appropriate tools. Alternatively, the easily removable 

plug-in transmitter card  with the sensor may be returned for service to IN

TEC

 Controls. 

12.4  Limited Warranty

 

MSR-Electronic-GmbH  and IN

TEC

 Controls warrants  the  PolyGard

®

transmitters for a period of (2) years 

from the date of shipment against defects in material or workmanship and 12 months normal exposure for 

sensor element. Should any evidence of defects in material or  workmanship occur during the warranty 

period, IN

TEC

 Controls will repair or replace the product at their  own discretion, without charge. 

This warranty does not apply to units that have been altered, had attempted repair, or been subject to 

abuse,  accidental or otherwise. The warranty also does not apply to units in which the sensor element 

has been  overexposed or gas poisoned. The above warranty is in lieu of all other express warranties, 

obligations or  liabilities. 
This warranty applies only to the PolyGard

®

transmitter.  MSR-Electronic-GmbH  and IN

TEC

 Controls 

shall not be liable for any  incidental or consequential damages arising out of or related to the use of the 

PolyGard

®

transmitters. 

If the PolyGard® transmitter needs to be returned to IN

TEC

 Controls for service, an RMA number must be 

obtained prior to sending. 

Specifications subject to change without notice. | USA 140403 | Page 13 of 13

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

AT-1193 – UserManual

Polygard® is a registered trademark of MSR | GAADT531193_E_1011.pdf

Specifications subject to change without notice. | USA 160104 | Page 13 of 13

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

AT-1193 – UserManual

PolyGard

®

 is a registered trademark of MSR-Electronic GmbH | GAADT531193_E_1011

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Specifications subject to change without notice. | GAADT531193_E_1011 | USA 200211 | Page 13 of 13

AT-1193 V3 – UserManual

Содержание AT03-005

Страница 1: ...Specifications subject to change without notice USA 140403 Page 1 of 13 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 7887 888 GO INTEC relevantsolutions com inteccontrols AT 1193 UserManual...

Страница 2: ...8 7 Troubleshooting 8 7 1 Analog Mode 8 8 Cross sensitivity Data 8 9 Technical Data 9 10 Figures 11 11 Part Disposal 13 12 Notes and General Information 13 12 1 Intended Product Application 13 12 2 I...

Страница 3: ...uses through a membrane filter into the liquid electrolyte of the sensor The chemical process of the measurement is one of reduction where one molecule of the target gas is exchanged for one molecule...

Страница 4: ...only in a duct system with a maximum air velocity of 10 m s 2000 ft min or less Mounting must be performed so that the probe openings are in line with the airflow 3 2 Installation Open the cover Unpl...

Страница 5: ...tion Please observe proper handling procedures for test gas bottles Attention CL2 calibration gas is toxic never inhale the gas Symptoms Chemical burn dizziness headache and nausea Procedure if expose...

Страница 6: ...il the signal is stable adjust control voltage with potentiometer Gain until the signal corresponds to the calculated value 2 mV see 5 3 3 Calculation of Control Voltage Remove calibration adapter wit...

Страница 7: ...etermined by the person responsible for the gas warning system according to the legal requirements INTEC Controls recommends checking the PolyGard Transmitter every three months and maintaining it eve...

Страница 8: ...ring Control voltage does not reach the calculated value Sensor element not calibrated Calibrate sensor element Sensor sensitivity 30 Replace sensor element No reaction of the output signal in spite o...

Страница 9: ...2 5 Electrical Power supply 18 28 VDC AC reverse polarity protected 2 wire mode only VDC Power consumption without options Analog mode 22 mA max 0 6 VA Output signal Analog output signal Selectable Cu...

Страница 10: ...8 EEC CE Approvals Enclosure Type A UL 508A Warranty Two years material and workmanship 12 months normal exposure for sensor element Options Relay output Alarm relay 1 switching threshold 5 ppm 30 VAC...

Страница 11: ...C Do not connect power supply at this pin 0 VDC 24 VAC or 0VAC will destroy the transmitter 0 VAC DC 24 VAC DC Do not connect 24 VAC at pin 2 and pin 4 or 24 VDC at pin 2 and 0 VDC at pin 4 Short circ...

Страница 12: ...ut V DC mA Anal Output Start Point 20 0 Function Relay R2 NO NC NC NO Manual Calibration 5 4 3 2 1 1 2 3 4 5 6 7 X5 X4 Specifications subject to change without notice USA 140403 Page 12 of 13 12700 St...

Страница 13: ...lectrical Code ANSI NFPA70 It is also essential to follow strictly all instructions as provided in the user manual 12 3 Maintenance It is recommended to check the PolyGard transmitter regularly Due to...

Отзывы: