FOR USE BY QUALIFIED PERSONNEL ONLY
Digital Controller
This controller has five (5) control features:
1. Temperature Scale
•
User can choose to read temperature in
°
C or
°
F
2. Temperature Setting
•
User can set heater temperature up to 225
°
C or 437
°
F.
3. Timer
•
User can set cycle time from 001 to 999 seconds.
4. Cycle Counter
•
Cycle counter can count up to 999 cycles. To reset,
press and hold the Reset button for 10 seconds.
5. Optional Offset Setting
•
There are two levels of temperature offset settings. Both
settings are pre-calibrated in factory. Do not alter these
settings unless otherwise directed by the manufacturer
service personnel.
Machine Control Setting
Controller Readout
•
OK:
Main button to scroll through 3 control
settings.
Temperature Scale
►
Temperature Setting
►
Timer
►
Confirm
•
▲
and
▼
: Increase or decrease number.
•
Reset:
Reset cycle counter to zero.
•
PV:
Present Value
•
SV:
Set Value
•
COUNTER:
Number of press cycles since last reset.
Controller Setting
•
Temperature Scale
a)
Press the
OK
button, either the “
°
C” or “
°
F”
icon starts blinking.
b)
Press
▲
or
▼
to change to “
°
C” or “
°
F”.
•
Temperature Setting
c)
Press
OK
again to set the transfer
temperature. Press
▲
or
▼
to increase or
decrease the temperature. Hold
▲
or
▼
for
faster change.
•
Timer
d)
After setting the temperature, press
OK
to set
the transfer time. Press
▲
or
▼
to increase
or reduce time.
NOTE:
The cycle time shall be added an additional 5
seconds to compensate the time required to
raise the platen upward before the substrate
seeing any temperature and pressure.
8