FOR USE BY QUALIFIED PERSONNEL ONLY
Air Source Connection
Connect air source hose to the inlet port of the
pressure regulator. The machine comes with
standard industrial
¼” quick connection male
coupling.
Machine installation requires at least two (2)
persons. Do not attempt to install machine alone.
Installation requires a Phillips head screwdriver and
a set of metric Allen wrenches.
In order to be able to move the machine with the
casters, the stand legs must be retracted. Use a
forklift to raise machine 6 inches off the floor, and
use a wrench to retract all four stands. Then slowly
lower the machine so is sitting on all four (4)
casters. Using at least two persons push the
machine to the desired location. Use caster locks to
keep the machine from further moving. Extend the
stand legs to secure the machine in place.
Electrical connections must be made by a
licensed electrician. DO NOT attempt to install
this machine with unqualified personnel.
Factory Electrical Requirements
Voltage
Requirement
3 Phase 208~230 VAC @60 Hz
Wiring
Requirement
Minimum AWG #12 Gauge
Fuse or
Breaker per
Phase
Minimum 25 Amp Rating
Wiring Declaration
Blue/Red/Black
Phase Line (Live)
Green
Ground Line
Machine Installation Instructions
5