Battery Replacement
153
3)
Status LED on front panel is abnormal
Description:
The server is under normal operation, but the status LED on front panel turns
red.
Suggestions:
a.
Firstly confirm which LED is abnormal according to the previous chapter about the LEDs
on the front panel.
b.
If the system failure LED is abnormal, check whether the system runs normally; if the
system runs normally, you can login to the BMC Web interface to view the BMC logs, to
check whether there are errors reported.
c.
If the power failure LED is abnormal, check whether the power module LED is normal; if
the power module LED is normal, you can login to the BMC Web interface to view the BMC
logs, to check whether there are errors reported.
d.
If other LEDs are abnormal, you can login to the BMC Web interface to view the BMC logs,
to check whether there are errors reported.
e.
If above operations could not resolve the problem, please contact Inspur customer service.
4)
Power module LED is off or red
Description:
The server is under normal operation, but a certain power module LED is off or red.
Suggestions:
a.
Firstly check whether all power cables are normal, and plug in the power cables again.
b.
If the fault still exists, insert the power module again.
c.
If shutdown is allowed, you could exchange the two power modules to judge whether it is
a power module fault.
d.
If above operations could not resolve the problem, please contact Inspur customer service.
5)
HDD status LED is abnormal
Description:
The server is under normal operation, but the HDD status LED is off or red.
Suggestions:
a.
If it is caused by manual operations, restore the array through RAID configuration.
b.
If there is no manual operations, check whether the HDDs are identified normally. If the
server is configured with an RAID card, login to the RAID management interface to check
whether there is an HDD failure.
c.
If there is an HDD failure, or the above operations could not resolve the problem, please
contact Inspur customer service.
Содержание AGX-5
Страница 1: ...Inspur Server User Manual NF5888M5 AGX 5 V1 1 ...
Страница 18: ...12 shown below ...
Страница 22: ...16 ...
Страница 37: ...31 Cabling Note Please route the cables according to the purchased machine configuration ...
Страница 46: ...40 Fig 2 11 Fig 2 12 Fig 2 13 ...
Страница 113: ...BMC settings 107 ...
Страница 116: ...110 ...
Страница 118: ...112 One key collect log One key collect log ...
Страница 123: ...BMC settings 117 ...
Страница 139: ...BMC settings 133 ...
Страница 142: ...136 ...
Страница 144: ...138 ...
Страница 149: ...BMC settings 143 ...