25
26
When “on” is selected “primer period = mmm: XXX”. Press up or
down to select from “0” to “120” minutes. Scroll right or left to
select Prime RPM, press up or down to select 1200 to 3300 in 25
RPM increments.
Please note: If RPM in prime RPM exceeds maximum current,
then pump is limited to speed at which maximum current is
drawn.
If “Auto Prime” is selected, the pump will run at maximum speed
until maximum current is reached for 5 seconds, then revert to
(a) timer speed or (b) previous selected speed (1) (2) (3) or (4)
in the case where the pump is turned on manually. If motor/
controller has not achieved maximum current for 5 seconds
within 5 minutes, the controller shuts the pump down.
Please note: Auto Prime is the factory default setting.
FUNCTION 4 – EXTERNAL TEMPERATURE SETTING (FREEZE
PROTECTION)
Press Function Button until F3 is selected to move to Prime
Menu.
Press up or down to select your preferred display in either “C”
(Celcuis) or “F” (Fahrenheit). If no external temperature sensor
is fitted to your Pump the display will show “0” values, contact
your pool professional to confirm if this is correct.