background image

25

26

When “on” is selected “primer period = mmm: XXX”.  Press up or 
down to select from “0” to “120” minutes.  Scroll right or left to 
select Prime RPM, press up or down to select 1200 to 3300 in 25 
RPM increments.

Please note:  If RPM in prime RPM exceeds maximum current, 
then pump is limited to speed at which maximum current is 
drawn.

If “Auto Prime” is selected, the pump will run at maximum speed 
until maximum current is reached for 5 seconds, then revert to 
(a) timer speed or (b) previous selected speed (1) (2) (3) or (4) 
in the case where the pump is turned on manually.  If motor/
controller has not achieved maximum current for 5 seconds 
within 5 minutes, the controller shuts the pump down.
Please note:  Auto Prime is the factory default setting.

FUNCTION 4 – EXTERNAL TEMPERATURE SETTING (FREEZE 
PROTECTION)

Press Function Button until F3 is selected to move to Prime 
Menu.

Press up or down to select your preferred display in either “C” 
(Celcuis) or “F” (Fahrenheit).  If no external temperature sensor 
is fitted to your Pump the display will show “0” values, contact 
your pool professional to confirm if this is correct.

Содержание Qi 1100

Страница 1: ...INSTALLATION OPERATING MANUAL Qi Variable Speed Pump A COMPLETE GUIDE TO YOUR SWIMMING POOL PUMP...

Страница 2: ...ped their product to provide you with the ultimate experience and are sure you will be delighted with your purchase THE IMPORTANT BITS SECTION 1 We care about your safety SECTION 4 Oops something not...

Страница 3: ...its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or metal capabilities or...

Страница 4: ...azardous voltage can shock burn and cause death or serious property damage To reduce the risk of electric shock do NOT use an extension cord to connect unit to electric supply Provide a properly locat...

Страница 5: ...readily disassembled for storage and reassembled to its original integrity TO REDUCE THE RISK OF ENTRAPMENT HAZARDS When outlets are small enough to be blocked by a person a minimum of two functioning...

Страница 6: ...and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangl...

Страница 7: ...0 LPM HEAD M 150 200 250 300 350 400 500 450 300 400 500 600 700 25 20 15 10 5 0 0 100 200 LPM HEAD M Pump maximum total head is 21 metres For optimal performance of your new Insnrg Pump we recommend...

Страница 8: ...ate lighting 1 Minimise the amount of PVC Pipe and Fittings through your filtration system The longer the pipe and the greater the amount of fittings the more pressure is built into the system and the...

Страница 9: ...level making the priming process quicker and easier Follow the steps below to prime the pump 1 Remove the pump lid and locking ring 2 Fill the pump strainer pot with water generally use a Bucket and o...

Страница 10: ...of a button The following section will outline what functions are available and how to access and operate PUMP SPEED CONTROL AND MONITORING CHANGING SPEEDS Your Insnrg Variable Speed Pool Pump has 4...

Страница 11: ...one press will put into Pump Timer Mode The Screen will display Auto on for 10 seconds and then flash Next timer period xx xx for 2 seconds When in timer period screen displays Auto On running til xx...

Страница 12: ...8pm Once happy with time setting either scroll left or right off the hour or minute or press the function button and the new hour or minute setting will be stored FUNCTION 2 TIMER SETTING Press funct...

Страница 13: ...nu or press the On Off Auto button to save settings and operate your pump FUNCTION 3 PRIME SETTING Press Function Button until F3 is selected to move to Prime Menu There are two choices using the Left...

Страница 14: ...to a timer speed or b previous selected speed 1 2 3 or 4 in the case where the pump is turned on manually If motor controller has not achieved maximum current for 5 seconds within 5 minutes the contr...

Страница 15: ...temperature will then be displayed then press up or down to change temperature from 40 F to 48 F or 4 4 C to 9 0 C depending on the setting choosen in Function 4 You must also select the Speed you wis...

Страница 16: ...e functions via Bluetooth on any SMART device TO SET UP THIS FEATURE YOUR WILL NEED TO COMPLETE THE FOLLOWING STEPS 1 Download the free INTOUCH App from your devices store ie Google Play App Store etc...

Страница 17: ...mal course of use and require regular checks and maintenance A well thought out pro active maintenance schedule with identify faults early and extend the lifespan of your pump To protect against extre...

Страница 18: ...s blocking movement inside the Pump Volute Empty Baskets and if necessary dismantle Pump to remove debris If warning still shows on screen contact your local pool professional for assistance WARNINGS...

Страница 19: ...Empty Leaves and other debris Quarterly Check all Gaskets Isolate and turn off the Pump Remove all Gaskets and turn over You can also apply a silicon based grease to extend the life If dry then conta...

Страница 20: ...Pump are correctly seated and sealed Fill Wet End of Pump with water as high as possible Check that water level in the Pool is high enough that water is drawing into the Skimmer Remove any suction cl...

Страница 21: ...for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a maj...

Страница 22: ...authorised service technician costs of technician s travel time if the defect is found not to be covered by the consumer guarantees In the case of returned product the authorised service technician or...

Страница 23: ...43 PRODUCTS IN PERFECT SYNERGY...

Отзывы: