INSTALLATION AND 

OPERATING INSTRUCTIONS 

                  

                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Melbourne: 03 8796 8600 

Gold Coast: 07 5552 2600 

Perth: 08 9350 2600 

Sydney:      02 9853 2100 

Townsville:   07 4750 3100 

[email protected] 

Brisbane:    07 3308 5400 

Adelaide:     08 8152 7600 

www.astralpool.com.au 

Bolero ND 

Cleaner 

Viron Cartridge Filter 

INSTALLATION AND OPERATING INSTRUCTIONS 

 

INSTALLATION AND OPERATING INSTRUCTIONS 

     Viron CL Series 
      Cartridge Filter 

 

 
 

Summary of Contents for CL Series

Page 1: ...h 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron CL Series Cartridge Filter ...

Page 2: ...Inst 249 Viron CL Series Cartridge Filter V0610 2 ...

Page 3: ...led below water level isolation valves must be installed on the inlet and outlet to enable the filter to be dismantled for cleaning without the loss of water from the pool or spa 6 It is also recommended that a three way valve be installed on the return line to allow draining of water from the pool or spa when necessary START UP INSTRUCTIONS Warning Never Start Pump while lid or lock ring is loose...

Page 4: ...ion and return lines 2 Open the air bleed valve on the lid 3 Loosen lock ring and remove cartridges 4 Lift out cartridges Clean the cartridge by soaking it in a mild solution of chlorine and warm water for 15 minutes and then hose off with high pressure water 5 Replace the cartridges carefully locating it on the bottom spigot 6 Clean the lid o ring Apply a small amount of water based lubricant 7 P...

Page 5: ... pool or in times where earthworks and construction are taking place nearby cleaning may be required as often as once per month NEVER LOOSEN THE LOCK RING WHEN THE PUMP IS WORKING MODEL PART NO ELEMENT PART NO FILTER AREA MAX FLOW RATE L Hr MAX FLOW RATE L M 4 HR TURN OVER 6 HR TURN OVER PUMP SIZE SHIP KG S CUBIC MEASURE CL400 10055 78083 400 sq ft 38 0 m2 42 000 700 168 000 252 000 750w 2200w 37 ...

Page 6: ... high pressure cleaner or purpose element cleaner Three Monthly Check inlet outlet o rings for leaks Check operation of pressure gauge salt water can prematurely reduce the life of a gauge Isolate Pump turn power off clean and grease O rings or replace if necessary Replace gauge if required Annually Compare operating pressure of a cleaned filter to initial pressure when new Also check for signs of...

Page 7: ...ield labour warranty applies only within capital city metropolitan areas or within 20 kilometers of an authorised AstralPool service agent Should you reside outside these locations a travel charge may apply Should the gauge or cartridge element fail it must be returned to AstralPool freight pre paid for repair or replacement at our option AstralPool shall not be responsible for consequential damag...

Page 8: ... South Australia Western Australia Gold Coast Townsville Ph 03 8796 8600 Ph 02 9853 2100 Ph 07 3308 5400 Ph 08 8152 7600 Ph 08 9350 2600 Ph 07 5552 2600 Ph 07 4750 3100 Fax 03 8796 8670 Fax 02 98532170 Fax 07 3308 5470 Fax 08 81527670 Fax 08 9350 2670 Fax 07 5552 2670 Fax 07 4750 3170 INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTR...