background image

INSTALLATION

MANUAL

Powered by

Summary of Contents for invermac inverFLOW Series

Page 1: ...INSTALLATION MANUAL Powered by ...

Page 2: ...NSTALLATION 4 1 Tools required 4 2 Pump Location 4 3 Piping 4 4 Valve and Fittings 4 5 Check before initial startup 4 6 Application conditions 5 SETTING AND OPERATION 5 1 Display on control panel 5 2 Startup 5 3 Self priming 5 4 Backwash 5 5 Manual inverter mode 5 7 Timer mode 5 8 Skimmer Mode 2 3 3 3 4 4 4 4 4 4 5 5 5 5 6 6 6 7 6 EXTERNAL CONTROL a Digital input b RS485 c Relay output optional 7 ...

Page 3: ... Max Flow L m Head Max m Circulation Power KW Power HP Flow at 8mh L min Flow at 10m L min 2 TECHNICAL SPECIFICATIONS 3 OVERALL DIMENSION mm 4 INSTALLATION 3 Safety Googles Gloves Philips Screwdriver Flathead Screwdriver Pipe Wrench Adjustable Wrench Multi Grips PVC Pipe Cutter Power Drill Tape Measure 4 1 Tools required INVERFLOW ULTRA Internal thread G2 External thread FBT 2 Internal thread G2 E...

Page 4: ...1 For optimization of the pool plumbing it is recommended to use a pipe with size of 63mm When installing the inlet and outlet fittings joints use the special sealant for PVC material 2 The dimension of suction line should be the same or larger than the inlet line diameter to avoid pump sucking air which will affect the efficiency of the pump 3 Plumbing on the suction side of the pump should be as s...

Page 5: ...mark The pump is delivered with self priming enabled Each time the pump restarts it will perform self priming automatically The user can enter the parameter setting to disable the default self priming function see 5 10 If the default self priming function is disabled and the pump has not been used for a long time the water level in the strainer basket may drop User can manually activate the self p...

Page 6: ...ng to the set running capacity or flow rate If the set time period does not contain the current time the timer number or 1 or 2 or 3 or 4 that is about to start running will be displayed on the controller and flash will display the corresponding time period indicating a successful timer setting All 4 time periods should be set in chronological order Overlap setting of time will be considered as in...

Page 7: ...e 5 Flow rate setting in the timer mode 3 3h 3 min 80 7 00 21 00 Not editable 1 Skimmer cycle hour 2 Skimmer duration minute 3 1 2 4 3 Skimmer mode preset number 4 Skimmer speed 5 10 Parameter Setting Restore factory setting Under off mode hold both for 3 seconds Check the software version Under off mode hold both for 3 seconds Manual priming Under on mode hold both for 3 seconds Enter parameter s...

Page 8: ... RELAY OUTPUT Brown L ACL ACN PE Blue N Yellow and Green Flow rate setting range INVULT300 83 333L min INVULT400 83 417L min INVULT500 83 500L min Connector for external control 1 2 5 7 6 3 4 8 INVERFLOW ULTRA Name Color Description PIN 1 Red Digital Input 4 PIN 2 Black Digital Input 3 PIN 3 White Digital Input 2 PIN 4 Grey Digital Input 1 PIN 5 Yellow Digital Ground PIN 6 Green RS485 A PIN 7 Brow...

Page 9: ... AL01 check the module temperature every 2 minutes Compared with the temperature in the previous period for every 1 degree Celsius increase the speed will decrease by 5 7 2 Undervoltage protection When the device detects that the input voltage is less than 200V the device will limit the current running speed When input voltage is less than or equal to 180V the running capacity will be limited to 7...

Page 10: ...rategy and 485 communication failure it will power off automatically and display an error code Errors can be sometimes caused by power surge or power interference and can be reset by Empty the strainer basket frequently The basket should be inspected through the transparent lid and emptied when there is an evident stack of rubbish inside The following instructions should be followed 1 Disconnected...

Page 11: ...ation timers Use quick connect cable pump output ELV socket Pump is activated by heater timer and temperature Plug water pump into sanitsation system Connect pump to heater with quick connect Pump Output ELV Plug water pump into Pump Controller Plug pump controller into Sanitisation Plug Quick connect from pump to controller Plug quick connect from heater to controller Power outlet A Chlorinator Q...

Page 12: ...airing Please make sure your pump is turned on before you start WiFi and Bluetooth 1 Please ensure your phone is connected to the home WiFi and has a strong connection at the pool pump location Also please enable Bluetooth 2 First Unlock the screen by holding the Unlock button for 3seconds until a beep noise can be heard and the screen is illuminated 3 Press button for 5 seconds until hearing a be...

Page 13: ...code list Real time running capacity Turn the control dial to set the flow rate Data On off Data On off Real time power consumption Real time power consumption Auto Inverter mode Manual Inverter mode Real time Flow rate Turn the control dial to set the running capacity Timer Backwash Timer Backwash 5 13 INVERFLOW ULTRA ...

Page 14: ... InverFlow first and then the adminstrator can operate as below If you have any problem while using welcome to send feedback Notice 1 Weather forecast is just for reference 2 The power consumption data is for reference only as it may be affected by network problems and imprecision of the calculation 3 App is subject to updates without notice Feedback 6 7 14 INVERFLOW ULTRA ...

Page 15: ...s illuminated 2 Press and hold and arrows for 4 seconds on until is displayed 3 Use the or arrow whilst on to adjust to the bottom number optimum stated on the table on the right side The Perfect Pairing uses the intelligent communicaiton functions of the pool heat pump to activate the speed required for the pool pump ensuring the most efficient solution for your pool and equipment Adaptive Flow Pe...

Page 16: ...t key 5 O ring for Transparent Lid 132 5 3mm 20 Inverter controller 6 Transparent Lid 21 Fan cover 7 Nut for lid 22 Motor 8 Open wrench 23 Base 9 Drain plug 24 Cross recess head screw 10 O ring 10 3mm 25 Sealplate 11 Pump body 26 Mechanical seal 12 O ring 71 4 5mm 27 Spring washer 13 Turnable ring 28 Nut for impeller 14 O ring 17 2 65mm 29 Diffuser 15 Impeller Explosive Diagram Code Explosive Diag...

Page 17: ...s General wear and tear of consumable items To the extent permitted by law Madimack s liability under any condition or warranty that cannot be legally excluded in relation to the supply of goods and services is limited to one of the following options Repairing the goods Replacing the goods with equivalent products or services Paying the cost of replacing the goods or providing equivalent products ...

Page 18: ...d of in domestic waste at the end of their service life Electrical and electronic appliances often contain valuable materials They also contain specific materials compounds and components which were essential for their correct function and safety These could be hazardous to human health and to the environment if disposed of with your domestic waste or if handled incorrectly Please do not therefore ...

Reviews: