WARNING
Risk of Electric Shock. Connect only to a branch circuit protected by a
ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if
you cannot verify that the circuit is protected by a GFCI.
WARNING
Risk of Electric Shock . The electrical equipment must be connected only
to a supply circuit that is protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be
tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push reset button. Power should be restored. If
the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI
interrupts power to the electrical equipment without the test button
being pushed, a ground current is flowing, indicating the possibility of
an electrical shock. Do not use this electrical equipment. Disconnect
the electrical equipment and have the problem corrected by a qualified
service representative before using.
CAUTION
This pump is intended for use with permanently-installed pools and may
be used with hot tubs and spas if so marked. Do not use with storable
pools. A permanently-installed pool is constructed in or on the ground
or in a building such that it cannot be readily disassembled for storage.
A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity.
TO REDUCE THE RISK
OF ENTRAPMENT
HAZARDS:
•
When outlets are small enough to be blocked by a person, a
minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. floor or wall), must be
installed a minimum of 1 metre (3 Feet) apart, as measured from near
point to near point.
•
Dual suction fittings shall be placed in such locations and distances
to avoid “dual blockage” by a user.
•
Dual suction fittings shall not be located on seating areas or on the
backrest for such seating areas.
•
The maximum water velocity through the suction outlet assembly and
its cover for any suction
•
outlet must not exceed the suction fitting assembly and it’s cover’s
maximum design flow rate. The suction outlet (drain) assembly and
its cover must comply with the latest version of ANSI/ASME A112.19.8,
the standard for Suction Fittings For Use in Swimming Pools, Wading
Pools, Spas, and Hot Tubs, or its successor standard, ANSI/APSP-16.
•
Never use Pool or Spa if any suction outlet component is damaged,
broken, cracked, missing, or not securely attached.
•
Replace damaged, broken, cracked, missing, or not securely attached
suction outlet components immediately.
•
In addition to the above instructions for two or more suction outlets
per pump, they must be installed in accordance with latest ASME,
APSP Standards and CPSC guidelines, and follow all National, State,
and Local codes applicable.
•
Installation of a vacuum release or vent system, which relieves