11
12
DIMENSIONS &
PERFORMANCE
CHARTS
MODEL
Qi 1100
Qi 1800
SPEED
i
ii
iii
iv
i
ii
iii
iv
VOLTS
230
230
230
230
230
230
230
230
RPM
2850
2300
1700
1150
2850
1700
1125
900
INPUT WATTS (W)
1050
538
227
140
1870
800
350
137
FLOW RATE (lpm)
300
240
180
120
602
360
240
120
FLOW RATE (gpm)
80
64
48
32
160
96
64
32
Head (m)
8.0
5.1
2.9
1.3
8.0
5.0
2.7
1.2
Current (Amps)
7.5
3.8
1.6
1.0
8.5
4.0
2.0
0.9
A
A
B
B
C
C
D
D
E
E
F
F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
FINISH:
DEBURR AND
BREAK SHARP
EDGES
NAME
SIGNATURE
DATE
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
SCALE:1:10
SHEET 1 OF 1
A3
WEIGHT:
PUMP
331mm
(13.0in)
371mm (14.6in
)
733mm (28.
9in
)
Qi 1100 PUMP - FLOW CHART
Qi 1800 PUMP - FLOW CHART
900 RPM 1125 RPM 1700 RPM MAX SPEED
900 RPM 1125 RPM 1700 RPM MAX SPEED
25
20
15
10
5
0
0
50
100
LPM
HEAD (M
)
150
200
250
300
350
400
500
450
300
400
500
600
700
25
20
15
10
5
0
0
100
200
LPM
HEAD (M
)
Pump maximum total head is 21 metres
For optimal performance of your new Insnrg Pump we
recommend installing the pump within 30 cm (1 ft) above water
level. If the pool pump needs to be elevated more than 1 m
(3 ft) above the water level of the pool, then a check valve is
recommended on the suction line to the pump.
If the pump is located below water level, isolation valves must be
installed on both the suction and return lines to prevent the back
flow of pool water during any routine or required servicing.
For electrical connection, install the pump such that any
disconnecting means and/or junction boxes are within sight of
the pump and at least 1.5 m (5 ft) horizontally from the edge of
the pool and/or spa. Choose a location that will minimize the
amount of elbows required in the PVC piping.
NOTE: In Canada, the minimum distance maintained from the
edge of the pool and/or spa as noted above must be 3 m (10 ft),
as required by the Canadian Electrical Code (CEC, CSA C22.1).
PUMP LOCATION AND
CLEARANCES