background image

DURA-GLAS and MAX-E-GLAS

CENTRIFUGAL PUMPS with TRAP

O   W   N   E   R ’   S

M   A   N   U   A   L

INSTALLATION, OPERATION & PARTS

Series

PE

PEA
P2R

P2RA

Sta-Rite Pool/Spa Group

293 Wright Street, Delavan, WI 53115

North America: 800-752-0183, FAX 800-582-2217 
International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245
www.sta-ritepool.com

Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA

Printed in U.S.A.   © 2001, Sta-Rite Industries, Inc.

S413

(Rev. 4/9/01)

This manual should be furnished to
the end user of this pump; its use will
reduce service calls and chance of 
injury and will lengthen pump life.

1917 0895 NF

Summary of Contents for 71532

Page 1: ...h America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga Ont Murrieta CA Printed in U S A 2001 Sta Rite Industries Inc S413 Rev 4 9 01 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life 1917 0895 NF ...

Page 2: ... The Sta Rite PE and P2R Series Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety Instructions 3 Installation 4 6 Electrical 7 9 Operation 10 11 Storage Winterizing 11 Pump Service 12 13 Troubleshooting Guide 14 Repair Parts List 15 17 Warranty 19 ...

Page 3: ...rapment certified covers See Page 5 4 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Release all air in system before testing Tighten Sta Rite trap lids to 30 ft lbs 4 1 kg m torque for testing Water pressure fo...

Page 4: ...looding Be protected from excess moisture Allow adequate access for servicing pump and piping Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign matter to col lect around the pump motor To avoid burns when handling the motor let it cool for 20 minutes before trying to work on it NOTICE Use Teflon tape or Plasto Joint Stik1 f...

Page 5: ...o reduce risk of suction entrapment do not exceed the rated flow rate of the suction fittings POOL PUMP SUCTION REQUIREMENTS Pump suction is hazardous and can trap and drown or disem bowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools spas ...

Page 6: ... outlet complies with the latest ASME SNSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications In any case do not exceed the suction fittings maxi mum designed flow rate If 100 of the pump s flow comes from the main drain system the maximum water velocity in the pump suction hydraulic system must be six feet per sec ond or less even if one ...

Page 7: ...company Grounding Bonding Install ground bond and wire motor according to local or National Electrical Code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access plate See Fig 3 use size and type wire required by code Connect motor ground terminal to electrical service ground Ground wire must be a copper conductor It should be the same size as the cu...

Page 8: ...ry Power Supply for Optional Timer Low Spd High Spd Circuit Protector Remote SPDT Switch Ground Green Common If using timer Connect Timer Motor to Low Speed Only Minimum switch and timer amp rating must equal Branch Fuse Rating given in Recommended Fusing and Wiring Data table A B L2 L1 230 Volt Lines Back of motor with Terminal Board 1168 0794 Figure 4C Wiring hook up diagram two speed motors A B...

Page 9: ...30 60 1 16 0 8 0 30 15 12 14 3 2 8 14 8 4 2 6 14 14 2 P2RA5F 182L 1 1 2 115 230 60 1 18 2 9 1 30 10 14 5 5 2 8 14 8 4 2 6 12 14 3 PE52F 183L 1 1 2 200 60 1 10 5 15 14 2 12 3 12 3 PEAXSSG 183 2 230 60 1 10 4 15 14 2 14 2 12 3 P2RA6G 183L 2 230 60 1 12 0 20 14 2 14 2 12 3 P2RAXG 183LS 2 230 60 1 12 0 20 14 2 14 2 12 3 PEAAXSSG 184 2 1 2 230 60 1 11 2 20 14 2 14 2 12 3 PE6H 185L LC 3 230 60 1 15 8 25...

Page 10: ...a flooded suction system unscrew and remove trap cover fill trap and pump with water Lubricate trap cover O Ring with petroleum jelly each time it is removed Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Pump should prime now Priming time will depend on vertical length of suc tion lift ...

Page 11: ...system Propylene glycol is non toxic and will not damage plastic system components other anti freezes are highly toxic and may also damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid condensation corrosion problems do not cove...

Page 12: ...o pressure in trap body remove cover unscrew by turning counterclockwise 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulled away from pump body 5 Remove five screws and washers holding diffuser to seal plate 6 Remove motor canopy Capacitor voltage can be dangerous Before proceeding short the capacitor terminals tog...

Page 13: ...ed shaft end and shaft shoulder until rubber drive ring hits shaft shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft clockwise this will automatically locate seal in seal plate NOTICE On models with impeller screw install impeller gasket and lock screw left hand thread turn counterclockwise 8 Mount diffuser on seal plate...

Page 14: ...er 7 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 12 check impeller for clogging follow steps 7 through 9 under Installing New Seal Page 13 for reassembly 8 Impeller and diffuser may be worn If so order replacement parts from Repair Parts List Pages 15 and 16 9 Pump may be trying to push too high a column of water If so a higher head pump is needed Electr...

Page 15: ... Capscrew 5 16 18x1 1 4 U30 64SS 4 U30 64SS 4 8 Washer Lock 5 16 U43 11SS 4 U43 11SS 4 9 Washer Flat 5 16 U43 41SS 4 U43 41SS 4 Quantity one unless otherwise indicated Overhaul Kits H P Parts Pak Number 1 2 PP1011 3 4 PP1014 1 PP1016 1 1 2 PP1018 Kit includes Impeller Diffuser Shaft Seal Gaskets O Rings Hardware Shims Wear Rings and Inserts Not available for two and three horsepower PE series pump...

Page 16: ...se U27 635 Decal IMPORTANT Do not use pipe dope WC27 27 Voltage Sticker 230 Volts U27 68 Voltage Sticker 115 230 Volts U27 153 Tag CAUTION 61002 0002 Tag WARNING 61002 0012 Tag CAUTION WARNING bonding C63 12 Nameplate U33 121 Not illustrated Models with LS suffix use Steel Base Part No J104 9C and Motor Pad Part No C35 5 Not used on models with LS suffix Models with LS suffix use 4 3 8x16x1 Capscr...

Page 17: ...L LS 2 230 60 1 A100GLL C105 137PDBA C1 200PA PEAAXSSG 184 2 1 2 230 60 1 AE100G5LL C105 137PD1A C1 200PAB PE6H 185L LC 3 230 60 1 AE100HLL C105 137PKBA C1 259P Uses one impeller screw Part No C30 12 Uses one impeller screw Part No C30 47 TWO SPEED MODELS Model HP Volts Hz Ph Motor Impeller Diffuser PEAXYE 181L 1 1 6 230 60 1 62003 2001 C105 138PEB C1 200PA P2RA5YE 181L LC 1 1 6 230 60 1 A100ELL Y...

Page 18: ...18 ...

Page 19: ...pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace the product covered by this warranty Requests for warranty service must be made through the in stalling dealer This warranty shall not apply to any product that has been subject to negligence misapplica...

Page 20: ...20 ...