‑91‑
Figure 3‑23 Main circuit wiring of three‑phase 380 V models
Note
●
1KM: Electromagnetic contactor; 1Ry: Relay; 1D: Flywheel diode
●
The DO is set as alarm output (ALM+/‑). When the servo drive alarms, the power
supply is cut off automatically and the alarm indicator lights up.
3.5.5 Wiring of External EMC Filter
Install the filter near the input terminals of the drive. The cable between the filter and
the drive must be shorter than 30 cm. Connect the grounding terminal of the filter
together with the grounding terminal of the drive. Ensure the filter and the drive are
installed onto the same conductive mounting surface that is connected to the main
grounding of the control cabinet.
Содержание SV660P Series
Страница 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Страница 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Страница 66: ...Wiring 65 3 3 2 Wiring Diagram for Torque Control Mode Figure 3 5 Wiring in the torque control mode...
Страница 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Страница 113: ...Wiring 112 Scheme 2 Using the external resistor...
Страница 135: ...Wiring 134 Selecting the regenerative resistor Figure 3 48 Flowchart for selecting the regenerative resistor...
Страница 144: ...Maintenance 143...