‑41‑
Note
●
Values inside the parentheses "()" are in British units.
●
The tightening tension for terminal screws must be between 0.19 N·m to 0.21
N·m, exceeding of which may damage the terminal.
●
For dimension drawings of motor models ending with "‑S", contact Inovance
technical support.
Dimension drawings of MS1H2 series motors
Figure 2‑14 Dimension drawing of MS1H2 series motors
Motor
Model
LC
LL
LR
LA
LZ
KA1
KB1
KA2
KB2
LG
LE
LJ
LB
Unit: mm (in.)
MS1H2‑
10C30CB(
D)‑A331Z
100
(3.94)
164
(6.46)
45±1
(1.77±0
.04)
115
(4.53)
4‑φ7
(0.16‑
φ0.28)
88
(3.46)
94.5
(3.72)
74
(2.91)
143.5
(5.65)
10
(0.39)
5±0.3
(0.20±
0.01)
2.5±0.75
(0.10±0.03)
95
(3.74)
MS1H2‑
10C30CB(
D)‑A334Z
213.5
(8.41)
101
(3.98)
192.5
(5.65)
MS1H2‑
15C30CB(
D)‑A331Z
100
(3.94)
189
(7.44)
45±1
(1.77±0
.04)
115
(4.53)
4‑φ7
(0.16‑
φ0.28)
88
(3.46)
119.5
(4.70)
74
(2.91)
168.5
(6.63)
10
(0.39)
5±0.3
(0.20±
0.01)
2.5±0.75
(0.10±0.03)
95
(3.74)
MS1H2‑
15C30CB(
D)‑A334Z
239
(9.41)
128
(5.04)
219.50
(8.64)
MS1H2‑
20C30CD‑
A331Z
100
(3.94)
214
(8.43)
45±1
(1.77±0
.04)
115
(4.53)
4‑φ7
(0.16‑
φ0.28)
88
(3.46)
144.5
(5.69)
74
(2.91)
193.5
(7.62)
10
(0.39)
5±0.3
(0.20±
0.01)
2.5±0.75
(0.10±0.03)
95
(3.74)
MS1H2‑
20C30CD‑
A334Z(‑S4)
265
(10.43)
153
(6.02)
244
(9.61)
Содержание SV660P Series
Страница 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Страница 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Страница 66: ...Wiring 65 3 3 2 Wiring Diagram for Torque Control Mode Figure 3 5 Wiring in the torque control mode...
Страница 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Страница 113: ...Wiring 112 Scheme 2 Using the external resistor...
Страница 135: ...Wiring 134 Selecting the regenerative resistor Figure 3 48 Flowchart for selecting the regenerative resistor...
Страница 144: ...Maintenance 143...