Copyright Innovative Technology Ltd 2008 GA794-2
4.2 CONFIGURATION BUTTON FUNCTIONS
The functions available via the Configuration Function Button are detailed in Table 6
Configuration Button
Power Status
Function
Press and Hold (>2 secs)
Powered ON
Sets BV20 to Programming
Mode (SSP)
Press Once (<1 sec)
Powered ON
Enables Configuration Card
Programming
Press Twice (within half a
second)
Powered ON
Current Setting Indicator
Press and hold
Powered OFF
Resets ccTalk key to Default
setting
Table 6
– Configuration Button Functions
BV20 Programming Mode
Press and Hold the Configuration Button for at least 2 seconds whilst the BV20 is powered
up. The Bezel LED will flash rapidly to indicate that SSP is being loaded. Once this process
has finished the BV20 will reset. The BV20 will now be in Programming Mode (SSP) and
allow connection to a PC via a DA1 or DA2 adapter or connection to a DA3.
Note: This mode can only be cancelled by re-programming with a Configuration Card or via
the Validator Manager program. Please ensure you are aware of all the BV20 programmed
settings before entering this mode. Failure to restore the original setting will stop the BV20
from operating in the Host machine.
Configuration Card Programming Mode
Press the Configuration Button once whilst the BV20 is powered up. If done correctly the
Bezel LED will flash every 1-second. This will allow the insertion of a Configuration Card to
change the Firmware Protocol in the BV20. (See Chapter 6 - Using Configuration Cards for
full details). This mode can be cancelled by again pressing the Configuration Button once.
Current Setting Indicator Mode
Press the Configuration Button twice within half a second whilst the BV20 is powered up.
The BV20 Bezel LED will then perform a series of flashes to indicate the current settings
within the validator. (See Program Check Procedure, in Appendix D)
Encryption Key Reset Function (ccTalk)
Note: This function will only be possible if the BV20 is programmed to ccTalk mode. It is not
possible to reset the key from SSP mode.
Press and hold the Configuration Button whilst the BV20 is powered off. Apply the power
and keep the button pressed for several seconds. The ccTalk Encryption Key will now be
restored to the default setting.
BV20 Operations Manual 9
Содержание BV20
Страница 1: ...Copyright Innovative Technology Ltd 2008 GA794 2 INTELLIGENCE IN VALIDAT BV20 OPERATIONS MANUAL ...
Страница 33: ...Copyright Innovative Technology Ltd 2008 GA794 2 BV20 EXPLODED ASSEMBLY DRAWING NUMBER GA792 ...
Страница 39: ...Copyright Innovative Technology GA794 2 ...
Страница 40: ...Copyright Innovative Technology GA794 2 ...
Страница 41: ...Copyright Innovative Technology GA794 2 ...
Страница 42: ...Copyright Innovative Technology GA794 2 ...