Copyright Innovative Technology Ltd 2008 GA794-2
1
2
16
15
If all four inhibits are high simultaneously then the BV20 will be disabled. In this state the
bezel will not illuminate and if a note is inserted the motor will run in reverse preventing
the insertion of the note. All four inhibits may be connected together to create a 'global'
inhibit. In this way the BV20 may be brought in and out of operation by the host machine.
Busy Output: (Pin 9). This is a general-purpose busy signal. It is active low while the BV20
is in operation.
Escrow Control: (Pin 10) Hold this pin low to enable the single note escrow function.
(Appendix B – ESCROW CONTROL).
It is possible to operate the BV20 in low power mode with the Parallel interface. For
further details please see Chapter 6.4.
5.2 PULSE STREAM OUTPUT
To use Pulse stream output for acceptance of up to 16 note/channel acceptance, The
Pulse interface must be programmed into the validator via the Configuration Cards (See
Appendix D – Configuration Cards) or via the ITL BNV Currency Manager program.
In Pulse mode the BV20 outputs a number of pulses on Vend 1. The number of pulses for
each channel is different and set to default values within the dataset. The number of
pulses and the pulse duration can be modified using the Validator Manager Software. A
maximum of 16 channels can be used.
Connections:
Pin
Name
Type
Description
1
Vend 1
Output
Credit pulse stream output.
2
Vend 2
Output
Not used
3
Vend 3
Output
Not used
4
Vend 4
Output
Not used
5
Inhibit 1
Input
Inhibit channel 1 by holding this pin HIGH, hold LOW to enable.
6
Inhibit 2
Input
Inhibit channel 2 by holding this pin HIGH, hold LOW to enable.
7
Inhibit 3
Input
Inhibit channel 3 by holding this pin HIGH, hold LOW to enable.
8
Inhibit 4
Input
Inhibit channel 4 by holding this pin HIGH, hold LOW to enable.
9
Busy
Output
Active LOW when the BV20 is transporting, reading or stacking
a note
10
Escrow
Input
Enable the escrow function by holding LOW (See Appendix B –
Escrow Control)
11
Factory use only
Do Not Connect
12
Factory use only
Do Not Connect
13
Factory use only
Do Not Connect
14
Factory use only
Do Not Connect
15
+Vin
Power
Nominal 12V DC supply
16 0V Ground
0V
supply
Table 8
– Pulse Mode Pin Description
BV20 Operations Manual 15
Содержание BV20
Страница 1: ...Copyright Innovative Technology Ltd 2008 GA794 2 INTELLIGENCE IN VALIDAT BV20 OPERATIONS MANUAL ...
Страница 33: ...Copyright Innovative Technology Ltd 2008 GA794 2 BV20 EXPLODED ASSEMBLY DRAWING NUMBER GA792 ...
Страница 39: ...Copyright Innovative Technology GA794 2 ...
Страница 40: ...Copyright Innovative Technology GA794 2 ...
Страница 41: ...Copyright Innovative Technology GA794 2 ...
Страница 42: ...Copyright Innovative Technology GA794 2 ...