Copyright ©2018, Infoblox, Inc.All right reserved.
exit Exit command interpreter
help Display help
ping Send ICMP ECHO
quit Exit command interpreter
reboot Reboot device
reset Reset system settings
set Set current system settings
show Show current system settings
shutdown Shutdown device
traceroute Route path diagnostic
ddns_add Send DDNS update to add a record
ddns_delete Send DDNS update to delete a record
rotate Rotate files
==============================================================================
For more detailed help about a given command, type 'help <command>'
For in-depth explanation of CLI command syntax, type
help
command after the command prompt. For example:
Infoblox > help rotate
Synopsis:
rotate log [ syslog | debug | audit | ifmapserver ]
rotate file groupname filename [ filename2, filename3, ...]
Description:
Rotates the specified log file, up to 10 previous.
logfiles will be preserved
The two main groups of NIOS CLI commands are
set
and
show.
To see the complete list of the
commands, enter
set
help set
after the
command prompt. Likewise, to see a complete list of the
show
commands, enter
help show
.
For information about the CLI commands, refer to the Infoblox CLI Guide.
Installing the Infoblox 4005 Series Appliance
Refer to the sections below to rack mount Infoblox 4005 Series appliances, connect them to a power source, and cable them to a network. Before
proceeding, review the
and follow the necessary precautions.
Infoblox Safety Guide
Note: Ensure that you install the appliance in an environment that allows open air to the front and back of the appliance. Do not obstruct the
appliance or block air flow going from the front to the back of the appliance.
Rack Mounting Procedures
The Infoblox 4005 Series appliances mount into a standard 19” (48 cm) equipment rack. The appliances ship with accessory kits that contain the
following: a pair of rack slide brackets and chassis slide rails, a pair of rack ears, eight (8) 10-32 screws, and eight (8) 8-32 screws. Infoblox also
offers a four-post and an adjustable rail four-post rack mounting kits that you can order separately. To mount the appliances to an equipment rack,
you also need a #2 screwdriver with a cross-headed tip.
You may rack mount Infoblox 4005 Series appliances in one of three ways:
Two-post rack mount, as described in
.
Two-Post Rack Mounting
Four-post rack mount, as described in
.
Four-Post 600mm Rack Mounting
Adjustable rail four-post rack mount, as described in
.
Adjustable Rail Four-Post Rack Mounting
Rack Mounting Safety Requirements
The following space and airflow requirements are required for Infoblox 4005 Series system operation:
Minimum clearance of 63.5 cm (25 in) in front of the rack
Minimum clearance of 76.2cm (30 in) in the rear of the rack
Minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or row of racks
The Infoblox appliance draws air in through the front of the chassis and expels air through the rear. Adequate ventilation is required to allow
ambient room air to enter the system chassis and to be expelled from the rear of the chassis.