Copyright ©2018, Infoblox, Inc.All right reserved.
5
(not used)
BI_DC-
White/Blue
White/Blue
6
Receive -
BI_DB-
Orange
Green
7
(not used)
BI_DD+
White/Brown
White/Brown
8
(not used)
BI_DD-
Brown
Brown
Legend: BI_D = bidirectional; A, B, C, D = wire pairings
10Base-T Ethernet and 100Base-T fast Ethernet use the same two pairs of wires. The twisted pair of wires
connecting to pins 1 and 2 transmit data, and the twisted pair connecting to pins 3 and 6 receive data.
1000Base-T connections use all four twisted-pair wires for bidirectional traffic.
Appliance Rear Panel
The Infoblox 4005 Series appliances ship with dual AC power supplies and six fan modules. The power supplies and fan modules are field
replaceable. The power supplies are also hot-swappable so you can replace any one of them at a time without disrupting the operations of the
appliance.
Infoblox 4005 Series, Rear View
Rear Panel Components
Component
Description
Fan Modules
Six field replaceable fan modules to help maintain optimum operating temperature. Each fan has an air vent that allows
warm air to flow out of the appliance. Do not obstruct.
UID LED
Blue = UID is activated through pressing the UID button on the appliance or through the Grid Manager or CLI command.
Dark = UID is deactivated