4
Chapter II System Installation and
Connections
2.1 Installation
Infinova recommends that the V2015A matrix switching system be
used in a standard 19-inch Electronic Industry Association (EIA)
rack. However, V2015A can also be configured for desktop use. It
is 5.24 inches in height by 19 inches in width and 12.8 inches in
depth.
Rack mounting instructions:
1.
Disconnect the power cord to ensure that there is no current
running through the system.
2.
Remove the four 1/4-inch flat-headed screws that hold the matrix
cover in place.
3.
Remove the four rubber feet from the bottom of V2015A.
4.
Locate V2015A ears on the rack.
5.
Mount V2015A using four 1/4-inch pan-headed screws.
Warning:
Improper airflow and ventilation may cause
unit to overheat or malfunction in certain circumstances.
Infinova recommends that the unit be installed with at
least three feet of space between the rack cabinet and any structure
or equipment and at least 1¾ inch between V2015A and other
rack-mounted devices.
2.2 Product View
2.2.1 Front Panel View
ALARM
RUN
VIDEO MATRIX SWITCHING SYSTEM
Infinova
R
Figure 2-1. V2015A Front Panel
The V2015A front panel features two LEDs that indicate system
status. The red ALARM indicator will light when V2015A receives
an alarm; the green RUN indicator will blink once each second
during normal operation.
2.2.2 Rear Panel Views
VIDEO OUTPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
1
2
3
4
5
6
7
8
9 10 11 12
15 16
13 14
B W
S B
W S
B
W S B W S
NO NC CM
ALARMS
CODE
RELAYS
PROG MON
RS232 PORTS
ETHERNET
POWER
230VAC
50Hz
1
2
3
5
4
6
7
8
9
NC
NO
CM
10
RS485
T+ T - GND
1
2
3
4
5
6
DATA LINE
11
Figure 2-2.V2015A-80
×
16 Rear Panel
(1)
80 BNC video inputs (75
Ω
terminated)
(2)
16 BNC video outputs for 75
Ω
terminated monitors
(3)
16 alarm inputs (normally open)
(4)
4 Manchester control code outputs
(5)
Power socket
(6)
2 alarm outputs
(7)
Programming Monitor (PGM) output
(8)
5 RS-232 ports
(9)
1 Ethernet port
(10)
1 RS-485 control code output
(11)
Data Line output
VIDEO OUTPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
1
2
3
4
5
6
7
8
9 10 11 12
15 16
13 14
B W S
B
W S
B W
S
B
W
S
NO NCCM
ALARMS
CODE
RELAYS
PROG MON
RS232 PORTS
ETHERNET
POWER
230VAC
50Hz
1
2
3
5
4
6
7
8
9
NC
NO
CM
10
RS485
T+ T - GND
1
2
3
4
5
6
11
DATA LINE
Figure 2-3. V2015A-64×16 Rear Panel
(1)
64 BNC video inputs (75
Ω
terminated)
(2)
16 BNC video outputs for 75
Ω
terminated monitors
(3)
16 alarm inputs (normally open)
(4)
4 Manchester control code outputs
(5)
Power socket
(6)
2 alarm outputs
(7)
Programming Monitor (PGM) output
(8)
5 RS-232 ports
(9)
1 Ethernet port
(10)
1 RS-485 control code output
(11)
Data Line output
VIDEO OUTPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
1
2
3
4
5
6
7
8
9 10 11 12
15 16
13 14
B W S
B
W S
B W
S
B W
S
NO NCCM
ALARMS
CODE
RELAYS
PROG MON
RS232 PORTS
ETHERNET
POWER
230VAC
50Hz
1
2
3
5
4
6
7
8
9
NC
NO
CM
10
RS485
T+ T - GND
1
2
3
4
5
6
11
DATA LINE
Figure 2-4. V2015A-48×16 Rear Panel
(1)
48 BNC video inputs (75
Ω
terminated)
(2)
16 BNC video outputs for 75
Ω
terminated monitors
(3)
16 alarm inputs (normally open)
(4)
4 Manchester control code outputs
(5)
Power socket
(6)
2 alarm outputs
(7)
Programming Monitor (PGM) output
(8)
5 RS-232 ports
(9)
1 Ethernet port
(10)
1 RS-485 control code output
(11)