20
Table 4-1. Monitor Arming Types
Code
Description
Arming Type Display
1 Single/Sequence/Instant Clear
SSI
2 Single/Sequence/Auto
Clear (after 20 seconds)
SSA
3 Single/Sequence/Manual
Clear (ACK key)
SSM
4 Single/Hold/Instant
Clear
SHI
5 Single/Hold/Auto
Clear
SHA
6 Single/Hold/Manual
Clear
SHM
7 Block/Sequence/Instant
Clear
BSI
8 Block/Sequence/Auto
Clear
BSA
9 Block/Sequence/Manual
Clear
BSM
10 Block/Hold/Instant
Clear
BHI
11 Block/Hold/Auto
Clear
BHA
12 Block/Hold/Manual
Clear
BHM
First Monitor Arming Type Display
Second Monitor Arming Type Display
13
Dual/Hold and Sequence/Instant Clear
DHI
DSI
14
Dual/Hold and Sequence/Auto Clear
DHA
DSA
15 Dual/Hold
and
Sequence/Manual Clear
DHM
DSM
16 Disarm
monitor
17
Acknowledge Enabled: gives Manual Clear a priority over Instant Clear and Auto Clear. It should be programmed only after
arming the monitors.
18
Acknowledge Disabled: prohibits Manual Clear in any Instant/Auto Clear mode. It should be programmed only after arming the
monitors.
4.7.4 Arming/Disarming Monitors:
Use the OFF and ARM keys of the Infinova Security series
keyboards to arm/disarm monitors:
ARM - arm monitors.
OFF - disarm armed monitors.
To arm a monitor:
1.
Place the key-switch in the PROGRAM position.
2.
Enter the desired Arming Type Code.
3.
Press the ARM key.
4.
Place the key-switch in the OPERATE position.
To disarm a monitor:
1.
Place the key-switch in the PROGRAM position.
2.
Call the armed monitor to be disarmed.
3.
Press the OFF key.
4.
Place the key-switch in the OPERATE position.
Note:
To confirm that a monitor is disarmed, press the ARM key. If
the "
DIS
" message is displayed, the system has been successfully
disarmed.