6
2.4 Hardware connections
Note:
Please ensure that all connections have been made correctly
before powering V2015A.
2.4.1 Video Input Connections
V2015A features BNC connectors that are labeled as 1 (Camera 1)
through 80 (Camera 80) for up to 80 composite video inputs. Video
is routed from an external video source (e.g., a camera) to a BNC
terminal on the V2015A rear panel.
Please refer to the following table to select appropriate coaxial
video cables:
Table 2-1. Coaxial Cable & Maximum Operating Distance
Coaxial Cable Type
Max. Transmission Distance
RG59/U
750 ft (229 m)
RG6/U
1000 ft (305 m)
RG11/U
1500 ft (475m)
CAM 1
CAM 2
VIDEO OUTPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
1
2
3
4
5
6
7
8
9 10 11 12
15 16
13 14
B W
S
B W
S
B W
S
B W
S
NO NC CN
ALARMS
CODE
RELAYS
PROG MON
RS232 PORTS
ETHERNET
POWER
NC
NO
CN
RS485
T+ T - GND
CAM 15
CAM 16
V2015
DATA LINE
1
2
3
4
5
6
Figure 2-6. Connecting Cameras
2.4.2 Control Code Connections
V2015A features 4 Manchester code outputs and one RS-485
control code output to provide complete control over Pan, Tilt, and
Zoom (PTZ) operations.
2.4.2.1 Manchester Code Connection
The transmitted Manchester Code is typically received by either the
V1690M receiver/driver, or Super Dome camera. Up to 3 receivers
can be daisy-chained together to increase the amount of units over
which the matrix has PTZ control.
If the application requires PTZ control for more than 4 locations, it
is recommended that the Infinova V2412 Manchester control code
distributor be used throughout the system.
Note:
For V2015A systems with less than or equal to 64 video
outputs, each of the four Manchester control code outputs can
perform PTZ control over any camera in the system (Shown in
Figure 2-7
).
But, for V2015A systems with 80 video outputs, the four
Manchester control code outputs are split into two groups,
respectively for PTZ control over
Cameras 1-64
and
Cameras
65-80
. While connecting receiver/drivers, please refer to the
guidelines in
Figure 2-8
and make sure that the receiver addresses
are appropriately associated with the cameras. For instance, the
receiver/driver for Camera 64 must be connected to one of the left
two outputs, and be configured with the
ID number of 64
. The
receiver/driver for Camera 65, however, must be connected to one
of the other two outputs on the right, and be configured with the
ID
number of 1 (65 - 64)
.
B
W
S
B
W
S
B
W
S
B
W
S
CODE
Camera 1 - 64
Receiver/driver ID = Camera ID
Figure 2-7. Manchester Control Code Outputs
B
W
S
B
W
S
B
W
S
B
W
S
CODE
Camera 1 - 64
Camera 65 - 80
Receiver ID = Camera ID
Receiver ID = Camera ID - 64
Figure 2-8. Manchester Control Code Outputs
Note:
While connecting receivers, please make sure that the
receiver addresses is associated with the cameras.
VIDEO
OUTPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
5
1
6
1
3
1
4
B
W
S
B
W
S B W
S
B W
S
ALARMS
CODE
RELAYS
PROG MON
RS232 PORTS
ETHERNET
POWER
NO
RS485
GND
PO
W
E
R
COD
E
W S B
PO
W
E
R
CO
DE
AU
X1
N/
C
AUX
1
N
/ O
AU
X2
N
/O
W S B
PO
W
E
R
COD
E
W S B
V2412M
Up to 16 V1690M Receivers can be connected to one
V2412M unit
Coaxial Cable
Control Signal
Cable
Control Signal Cable
MANCHESTER
CODE INPUT
B W S
V2015
Super Dome
NC
NO
NC CM
CM
T+ T-
V1690M
120 Ohm
120 Ohm
120 Ohm
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
DATA LINE
24V
A
C
AUX2
CO
M
AUX
1
CO
M
-
RE
F
+
REF
PA
N
1
P
O
T
PA
N
2
P
O
T
TI
LT
PO
T
F
O
CUS
PO
T
Z
OOM
P
O
T
24V
A
C
AUX2
N
/C
AU
X2
N/
O
24
V
A
C
AUX2
CO
M
AUX1
COM
-
REF
+
REF
PAN1
P
O
T
PAN2
PO
T
TI
LT
PO
T
F
O
CUS
POT
ZO
O
M
PO
T
24V
A
C
AUX2
N
/C
AUX1
N
/C
AUX
1
N
/O
AUX2
N
/O
24V
A
C
AU
X2
COM
AU
X1
CO
M
-
REF
+ RE
F
P
AN1
PO
T
P
AN2
POT
TI
LT
PO
T
FO
C
U
S
PO
T
ZO
O
M
PO
T
24V
A
C
AUX
2
N
/C
AUX
1
N
/C
AU
X
1
N
/O
V1690M
V1690M
1
2
3
4
5
6
SH
E
L
D
I
SH
ELDI
SH
ELDI
Figure 2-9. Connecting Super Dome, V2412M and V1690M Units
2.4.2.2 RS-485 Control Code Connection
The RS-485 control code output of V2015A is typically used to
drive SAMSUNG or PELCO-P/D protocol receivers or dome
cameras. (See
5.6.2 Set RS-485
for how to select a output protocol.)
The RS-485 output terminal is designated as T+, T- and G.ND.