ImpulseRadar PinPointR User Manual V1.5
Page 28 (36)
At high survey speeds and short point intervals, the system will rarely be able to go beyond 16-bits;
therefore, the load on the Wi-Fi data link may be reduced by choosing to collect 16-bit data, instead
of 32-bit data.
Choosing an unnecessarily long time-window (number of samples) also increases the demand for data
transfer, so selecting a suitable time-window for each project is highly recommended.
Finally, the PinPointR, like all GPR systems, will lose lateral-resolution at depth. This decreases the
demand on the point interval, so no need to collect data any denser than necessary, concerning the
targets you want to resolve. Thus, increasing the point interval also takes the load off the Wi-Fi data-
link. By default, the minimum point interval is set to 1 cm.