Temperature Control
Temperature Control allows you to set the fan’s operation mode and the temperature at which
the fan turns on in Auto mode.
The fan automatically turns on—even if the fan operation mode is Off—
when the internal camera temperature exceeds 65 °C.
Parameter Name
Type
Value
Access Description
FanMode
Enumeration
String
Off
On
Auto
Num.
0
1
2
RW
Sets the operation mode of the
camera fan.
FanOnTemperature
Float
RW
Sets the temperature, in Celsius
degrees, when the camera fan turns
on to cool the camera (in Auto
mode). Fan turns off when the
internal camera temperature is 4 °C
below the set temperature.