STEP 4: Add Defective Pixel Coordinates to Defective Pixel Map
Place the defective pixel coordinates in the Defective Pixel Map file in ascending (increasing)
numerical order of the Y (row) coordinate. The value of all Y coordinates should progressively
increase as you look down the list of X, Y coordinates.
Example 1: Different Y coordinates
Example 2: Identical Y coordinates
-- Defective Pixel Map,
-- Date: 5.18.2020,
-- Model#: SFP-C6440M-RF,
-- Serial#: LAC001,
:Table,
-- Column(X),Row(Y)
701,1017
100,1018
4325,1019
2241,1020
458,1021
1712,1053
914,1067
3954,1546
2516,1670
3451,3331
1111,4149
95,
4364
594,
4817
433,
4828
-- Defective Pixel Map,
-- Date: 5.18.2020,
-- Model#: SFP-C6440M-RF,
-- Serial#: LAC001,
:Table,
-- Column(X),Row(Y)
650,
1017
698,
1017
701,
1017
100,1018
4325,1019
2241,1020
458,1021
1712,1053
f914,1067
3954,1546
2516,1670
3451,3331
1111,4149
95,4364
433,4828
As shown in the
Example 1
above, the Y coordinate of
594, 4817
is higher than
4364
and lower
than
4828
. Do not add defective pixel coordinates at the end of the list unless the Y coordinate is
the highest of all Y values.
If adding a defective pixel with a Y location identical to one or more other
defective pixels, insert its coordinates based on the order of increasing X
location.
As shown in the
Example 2
above, the Y coordinate of
698, 1017
is identical to two other
defective pixels. Place its coordinates between
650,
1017 and
701,
1017 because its X location
(698) is higher than 650 but lower than 701.
STEP 5: Save your DPM/HPM
•
Save your Defective Pixel Map with the file extension .dpm.
•
Save your Hot Pixel Map with file extension .hpm.
Row coordinates are
in ascending order
(increasing Y values).
Column coordinates are in
ascending order (increasing
X values).