Instructions for the installer
Danger!
Electrical installation must only be carried out by
an authorised company.
Electrical connection to the mains power supply.
This connection must be set up by state of the art, as
envisioned by regulations in force.
Remember that it is necessary to install a bipolar
switch on the electrical supply to the boiler with a
max distance between the contacts of 3 mm, easy to
access, so that maintenance operations can be carried
out quickly and safely.
Electrical supply connection
The electrical supply to the boiler, 230 V - 50 Hz
single-phase, must be carried out with a H05VV-F
(PHASE - NEUTRAL - GROUND) three-pole cable
with a section between 0.75 mm and 1.5 mm
ATTENTION!
Respect the PHASE and NEUTRAL polarity since
flame detection is Phase Sensitive.
ATTENTION:
Cables carrying a voltage of 230 V must travel sepa-
rately from cables carrying a voltage of 24 V.
52
M2
Additional terminal board +24V BCM
Connections to the additional BCM terminal board