13
1
2
3
4
6
5
7
8
1-18
C
12
1-19
1
3
2
5 6
4
C
32
1-21
1-20
C
32
C
12
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
end of the adapter (3) (with lip gasket) up to the
end stop; making sure that the wall sealing plate
(4) has been fitted, this will ensure sealing and
joining of the elements making up the kit.
• Coupling extension pipes and concentric
elbows. To install any push-fit extensions with
other flue extraction elements, it is necessary
to do the following: install the concentric pipe
or elbow with the male side (smooth) on the
female section (with lip seal) to the end stop
on the previously installed element. This will
ensure the sealing and joining of the elements
correctly.
Attention:
if the exhaust terminal and/or con-
centric extension pipe needs shortening, consider
that the internal duct must always protrude by 5
mm with respect to the external duct.
This specific terminal enables flue exhaust and
air intake, necessary for combustion, in a verti-
cal direction.
N.B.:
the Ø 80/125 vertical kit with aluminium
tile enables installation on terraces and roofs with
a maximum slope of 45% (25°) and the height
between the terminal cap and half-shell (374
mm) must always be respected.
The vertical kit with this configuration can be
extended to a
max. straight vertical length of
12200 mm
including the terminal (Fig. 1-21).
This configuration corresponds to a resistance
factor of 100. In this case specific extensions
must be requested.
The terminal Ø 60/100 can also be used for
vertical exhaust, in conjunction with concentric
flange code 3.011141 (sold separately). The height
between the terminal cap and half-shell (374
mm) must always be respected.
The vertical kit with this configuration can be
extended to a
max. straight vertical length of 4700
mm
including the terminal (Fig. 1-21).
Separator kit Ø 80/80.
The separa-
tor kit Ø 80/80, enables separation of the
exhaust flues and air intake pipes accord-
ing to the diagram shown in the figure.
Combustion products are expelled from pipe (S).
Air is taken in through pipe (A) for combustion.
The intake pipe (A) can be installed either on the
right or left hand side of the central exhaust pipe
(S). Both ducts can be routed in any direction.
• Kit assembly (Fig. 1-22): install the flange (4)
on the central hole of the boiler, interposing
the gasket (1) and tighten with the flat-tipped
hex screws included in the kit. Remove the flat
flange present in the lateral hole with respect
to the central one (according to needs) and
replace it with the flange (3), positioning the
gasket (2) already present in the boiler and
tighten using the supplied self-threading
screws. Fit the male end (smooth) to the bends
(5) in the female end of the flanges (3 and 4).
Fit the intake terminal (6) with the male section
(smooth) in the female section of the bend (5)
up to the end stop, ensuring that the internal
and external wall sealing plates are fitted. Fit the
exhaust pipe (9) with the male end (smooth) to
the female end of the bend (5) up to the stop;
making sure that the internal wall sealing plate
has been fitted, this will ensure sealing and
joining of the elements making up the kit.
• Coupling of extension pipes and elbows. To
install any push-fit extensions with other flue
extraction elements, it is necessary to do the
following: install the pipe or elbow with the
male side (smooth) on the female section
(with lip seal) to the end stop on the previously
installed element. This will ensure the sealing
and joining of the elements correctly.
• Installation clearances. Figure 1-23 gives the
The kit includes:
N°1 - Gasket (1)
N°1 - Concentric bend Ø 60/100 (2)
N°1 - Adapter Ø 60/100 for Ø 80/125 (3)
N°1 - Concentric intake-exhaust terminal
Ø 80/125 (4)
N°1 - Internal white wall sealing plate (5)
N°1 - External grey wall sealing plate (6)
Max 7300
Max 7195
The kit includes:
N°1 - Gasket (1)
N°1 - Female concentric flange (2)
N°1 - Adapter Ø 60/100 for Ø
80/125 (3)
N°1 - Wall sealing plate (4)
N°1 - Aluminium tile (5)
N°1 - Int./exhaust concentric pipe Ø
80/125 (6)
N°1 - Fixed half-shell (7)
N°1 - Mobile half-shell (8)
MAX
45%
MAXIMU
M LEN
GTH 12200 mm
MAX
45%
MAXIMU
M LEN
GTH 4700 mm