Immergas 3.020928 Скачать руководство пользователя страница 27

27

3-3

4

3

2

1

5

6

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

Key:

  1 -  Coil

  2  -  Minimum power adjustment screw

  3  -  Maximum power adjustment nut

  4  -  Gas valve outlet pressure point

  5  -  Gas valve inlet pressure point

  6  -  Protection hood

SIT 845 GAS Valve

carried out by a qualified company (e.g. Author-

ised After-Sales Assistance). Burner adjustment 

must be carried out using a differential "U" or 

digital type pressure gauge connected to the 

pressure socket located above the sealed cham-

ber (part. 9 Fig. 1-30) and the gas valve pressure 

outlet (part. 4 Fig.  3-3), keeping to the pressure 

value given in the table (Par. 3.18) according to 

the type of gas for which the boiler is prepared.

3.8  POSSIBLE ADJUSTMENTS.

N.B.: 

to adjust the gas valve, remove the plastic 

cap (6); after adjusting, refit the cap.
• Preliminary calibration operations.
  - Set parameter S0 at 0 %.
  - Set parameter S1 at 99 %.
• Activate the chimney sweep function.
  - Enter the “DHW chimney sweep” mode, 

opening a DHW cock.

  

Attention:

 if the boiler is set-up solely for 

central heating, calibrate with chimney sweep 

in "central heating" mode.

• Adjustment of boiler nominal thermal heat 

output.

  -  Set the power at maximum (99%) by turning 

the “CH regulator” selector (1).

  - With the brass nut (3 Fig. 3-3) adjust the 

boiler nominal output, observing the maxi-

mum pressure values stated in the tables (Par. 

3.18) according to the type of gas; by turning 

clockwise the heat potential increases, anti-

clockwise it decreases.

• Adjustment of boiler minimum thermal heat 

output.

 

N.B.:

 only proceed after having calibrated the 

nominal pressure.

  - Set the power at minimum (0%) still using 

the “CH regulator” selector (1).

  - Adjust the minimum thermal input by op-

erating on the cross plastic screws (2) on the 

gas valve maintaining the brass nut blocked 

(3);

• Exit the “Chimney sweep” mode and keep the 

boiler functioning.

•  Adjustment of the boiler minimum heat output 

in heating phase.

 

N.B.:

 only proceed after having calibrated the 

minimum boiler pressure.

  - To adjust the minimum heat output during 

the heating phase, change parameter (S0), 

increasing the value the pressure increases, 

reducing it the pressure drops.

  - The pressure to which the boiler minimum 

heat output must be adjusted, must not be 

lower than that stated in the tables (par. 3.18).

• Adjustment (any) of the boiler maximum heat 

output in central heating phase.

  To adjust the maximum heat output during 

the heating phase, change parameter (S1), 

increasing the value the pressure increases, 

reducing it the pressure drops.

  - The pressure at which the maximum boiler 

heat output must be set in the central heating 

stage.

3.9  SLOW AUTOMATIC IGNITION 

FUNCTION.

In ignition phase, the P.C.B. supplies constant 

gas with pressure proportional to the parameter 

"S4" set.

3.6  CONVERTING THE BOILER TO 

OTHER TYPES OF GAS.

If the boiler has to be converted to a different 

gas type to that specified on the data nameplate, 

request the relative conversion kit for quick and 

easy conversion.

The gas conversion operation must be carried 

out by an authorised company (e.g. Authorised 

Technical After-Sales Service).

To convert to another type of gas the following 

operations are required:

- disconnect the appliance;
-  replace the main burner injectors, making sure 

to insert the special seal rings supplied in the 

kit, between the gas manifold and the injectors;

- re-power the appliance;
-  from the push button panel on the boiler, select 

the type of gas (S2) and then select (

Ng

) if it 

runs on Methane or (

Lg

) if it runs on LPG;

- adjust the boiler nominal heat output;
- adjust the minimum heat power of the boiler;
-  adjust the boiler nominal heat output in heating 

phase;

- adjust (eventually) the maximum heating 

power;

-    seal the gas flow rate regulation devices (if 

settings are modified);

- after completing the conversion, apply the 

sticker, contained in the conversion kit, near 

the data nameplate. Using an indelible marker 

pen, delete the data relative to the old type of 

gas.

These adjustments must be made with reference 

to the type of gas used, following that given in 

the table (Par. 3.18).

3.7   CHECKS FOLLOWING 

CONVERSION TO ANOTHER TYPE 

OF GAS.

After making sure that conversion was carried 

out with a nozzle of suitable diameter for the 

type of gas used and the settings are made at the 

correct pressure, check that:

-   there is no flame in the combustion chamber
-   the burner flame is not too high or low and 

that it is stable (does not detach from burner)

-   the pressure testers used for calibration are 

perfectly closed and there are no leaks from 

the gas circuit.

N.B.:

 all boiler adjustment operations must be 

Содержание 3.020928

Страница 1: ...MAIOR EOLO X 28 Instruction and recommendation booklet 1 038769ENG...

Страница 2: ......

Страница 3: ...specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits esta...

Страница 4: ...ce 19 2 2 General warnings 19 2 3 Control panel 19 2 4 Using the boiler 20 2 5 Troubleshooting 21 2 6 Boiler shutdown 22 2 7 Restoring central heating system pressure 22 2 8 System draining 22 2 9 Ant...

Страница 5: ...ances underneath the boiler as they could be damaged if the safety valve intervenes if the drain trap is blocked or if there are leaks from the hydraulic connec tions otherwise the manufacturer cannot...

Страница 6: ...ts the central heating circuit from freez ing by introducing a top quality anti freeze liquid into this circuit which is not noxious to health The instructions of the manufacturer of this liquid must...

Страница 7: ...cal standards in force in order to protect the system and the appliance from deposits e g scale slurry or other hazardous deposits Water connections must be made in a rational way using the couplings...

Страница 8: ...h its climate thermostat function disabled i e it must be set to On Off mode Comando Amico Remoto Remote Control V2 or On Off chrono thermostat electrical con nections Optional The operations describe...

Страница 9: ...haust in individual flue or to the outside The boiler with this type of configuration is classified as type B22 in accordance with the technical standards in force With this configuration air intake t...

Страница 10: ...with the boiler as standard DIAPHRAGM Shutter regulation table Flue gas shutter notch Type of installation duct length in metres 2 4 7 10 60 100 horizontal concentric kit From 0 to 0 5 From 0 5 to 1...

Страница 11: ...6 Exhaust m 2 0 Terminal complete with concentric vertical intake exhaust 80 125 Intake and Exhaust 33 m 2 0 m 5 5 Intake m 14 3 Exhaust m 11 0 Concentric vertical intake exhaust termi nal 80 125 Inta...

Страница 12: ...it 80 125 Kit assembly Fig 1 18 install the bend with flange 2 onto the central hole of the boiler inserting the gasket 1 and tighten using the screws in cluded in the kit Fit the male end smooth of t...

Страница 13: ...in the figure Combustion products are expelled from pipe S Air is taken in through pipe A for combustion The intake pipe A can be installed either on the right or left hand side of the central exhaust...

Страница 14: ...screws included in the kit Remove the flat flange present in the lateral hole with respect to the central one ac cording to needs and replace it with the flange 3 positioning the gasket 2 already pre...

Страница 15: ...gas exhaust outlets to the same height Temperature loss in insulated flue ducting To prevent problems of flue gas condensate in the insulated exhaust pipe 80 due to flue gas cooling through the wall t...

Страница 16: ...edatlowspeedtoensurerelease of air bubbles in the water via the boiler and heating system vents The boiler has a built in automatic venting valve on the circulator Check if the cap is loose Open the r...

Страница 17: ...n type B it is compulsory to mount the appropriate top protection cover along with the flue exhaust kit Anti freeze kit with resistance on request If the boiler is installed in a place where the tempe...

Страница 18: ...itive signal pressure point 8 Negative signal pressure point 9 Flue pressure switch 10 Flow probe 11 Fumes hood 12 Safety thermostat 13 Primary heat exchanger 14 Ignition and detection electrodes 15 S...

Страница 19: ...cal power requires some funda mental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the appli ance...

Страница 20: ...to the boiler being powered without presence of flame Each time the burner ignites the relative flame present symbol is displayed 11 with relative output scale Operation with Comando Amico RemotoV2 C...

Страница 21: ...nables fan start up incorrectly or in the event of a flue gas pressure switch fault If normal conditions are restored the boiler restarts without having to be reset 1 12 Storage tank probe anomaly If...

Страница 22: ...y of the appliance and the domestic hot water heating system in areas where the temperature falls below zero we recommend protecting the central heating system with anti freeze liquid and installing t...

Страница 23: ...and that the manometer indicates a pressure of 1 1 2 bar make sure the air valve cap is open and that the system is well deaerated switch the boiler on and check correct ignition make sure the gas ma...

Страница 24: ...minating resistance R8 The connector X5 is used for the connection to the relay board The connector X6 is for connection to a personal computer The connector X8 is used for software updating operation...

Страница 25: ...he type of gas being used S3 Boiler type Establishes the boiler type and its functioning mode 0 combi 1 24 kW storage tank 2 28 kW storage tank 3 32kW storage tank 0 3 2 S4 Power block Establishes the...

Страница 26: ...0 P5 Relay 3 optional The boiler is set up for functioning with the relay P C B optional which can be configured 0 Off 1 Chiller remote activation 2 General alarm 3 CH phase active 4 External gas val...

Страница 27: ...be adjusted must not be lower than that stated in the tables par 3 18 Adjustment any of the boiler maximum heat output in central heating phase To adjust the maximum heat output during the heating ph...

Страница 28: ...tion of approx 10 seconds N B during self check the boiler remains off including signalling 3 15 SOLAR PANELS COUPLING FUNCTION In the event of integration of DHW heating with solar panel systems for...

Страница 29: ...the guard a 3 Unhook the decorative frame c from the relative lower retainers 4 Remove the decorative frame c from the cas ing e 5 Loosen the 2 front screws d that fasten the casing 6 Loosen the 2 lo...

Страница 30: ...30 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN...

Страница 31: ...7 22 0 18920 2 49 7 43 75 8 1 86 18 61 189 8 1 83 22 76 232 1 21 0 18060 2 38 6 82 69 6 1 78 17 24 175 8 1 75 20 92 213 4 20 0 17200 2 27 6 24 63 7 1 70 15 91 162 3 1 67 19 18 195 6 19 0 16340 2 17 5...

Страница 32: ...eat output useful kW kcal h 11 2 9632 Efficiency at nominal heat output 94 3 Efficiency at 30 nominal heat output load 91 5 Heat loss at case with burner On Off 0 0 0 53 Heat loss at flue with burner...

Страница 33: ...odel code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH m...

Страница 34: ......

Страница 35: ......

Страница 36: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Отзывы: