2.4  USING THE BOILER.

Attention:

 the Maior Eolo X 28 boiler has been 

designed to operate as an appliance for room 

central heating only or, coupled with a specific 

optional kit, for central heating and the produc-

tion of DHW. For this reason the boiler control 

panel has a button to adjust the temperature of 

DHW, but its operation is only activated by the 

optional kits that also enable the production of 

DHW. Without the combination of these specific 

kits, the operation of this button and all functions 

referring to the DHW are inhibited.
Before ignition make sure the heating system 

is filled with water and that the manometer (2) 

indicates a pressure of 1 ÷ 1.2 bar.

- Open the gas cock upstream from the boiler.
- Press the button (3) until the display switches 

on. The boiler now returns to the state prior to 

switch-off.

-  If the boiler is in stand-by, press the button (3) 

again to activate it. If this is not the case, go to 

the next point.

- Then press the button (4) in sequence and set 

the boiler in the summer (

) or winter (

) position.

• 

Summer 

(

)

:

 in this mode the boiler only 

works to produce DHW 

(when the boiler is 

connected to the external storage tank unit)

; the 

temperature is set via the selector (2) and the 

relative temperature is shown on the display 

via the indicator (17).

  During a request for DHW the indicator (16) 

switches on. Upon ignition of the burner, the 

flame presence indicator (11) with relative 

power scale switches on and the indicator (17) 

shows the instant outlet temperature from the 

primary heat exchanger.

• Winter 

(

)

:

 in this mode, the boiler works to 

produce DHW 

(when the boiler is connected to 

the external storage tank unit)

 as well as central 

heating. The temperature of the DHW is always 

regulated via the selector (2), the heating tem-

perature is regulated via selector (1) and the 

relative temperature is shown on the display 

via the indicator (21).

  During a request for CH the indicator (12) 

switches on. Upon ignition of the burner, the 

flame presence indicator (11) with relative 

power scale switches on and the indicator (21) 

shows the instant outlet temperature from the 

primary heat exchanger. In the central heating 

phase, if the temperature of the water contained 

in the system is sufficient to heat the radiators, 

the boiler can only function with the activation 

of the boiler pump (indicator 12 on).

From this moment the boiler functions automati-

cally. With no demand for heat (central heating 

or domestic hot water production) the boiler 

goes to “standby” function, equivalent to the 

boiler being powered without presence of flame. 

Each time the burner ignites, the relative flame 

present symbol is displayed (11) with relative 

output scale.
• 

Operation with Comando Amico Remoto

V2

 

(CAR

V2

) (Optional)

. If the CAR

V2

 is connected, 

the (

) symbol will appear on the display. 

The boiler regulation parameters can be set via 

the CAR

V2

 control panel and the reset button 

(5) remains active on the boiler control panel, 

along with the switch-off button (3) (“off ” 

mode only) and the display where the function-

ing state is shown.

  

Attention:

 If the boiler is put into "off" mode, 

the “ERR>CM” connection error symbol will 

appear on the CAR

V2

. The CAR

V2

 is however 

powered constantly so as not to loose memo-

rised programs.

• 

Solar operating mode (

).

 This function 

cannot be activated on this boiler model.

• 

Domestic hot water priority function (

).

 Pressing the Boost button (6) disables the 

D.H.W. priority function, which is indicated 

by the symbol (20) switching off on the display. 

The disabled function keeps the water con-

tained in the storage tank at a temperature of 

10°C for 1 hour, giving the functioning priority 

to room central heating.

 

Attention:

 in the event of switching to the 

Stand-by/Off mode, with subsequent ignition 

(Summer/Winter) the D.H.W. priority function 

becomes active again.

• 

Operation with optional external probe 

(

)

.

 In the case of a system with optional 

external probe, the boiler flow temperature 

for room central heating is managed by the 

external probe depending on the external 

temperature measured (Par. 1.6). The flow 

temperature can be modified by selecting the 

functioning curve via selector (1), selecting a 

value from "0 to 9" (Fig. 1-6).

  With external probe present, the relative 

symbol (19) will appear on the display. In the 

central heating phase, if the temperature of the 

water contained in the system is sufficient to 

heat the radiators, the boiler can only function 

with the activation of the pump.

• 

“Stand-by” mode.

 Press button (3) until the 

(

) symbol appears. The boiler remains 

active from this moment and the anti-freeze 

function, pump anti-block function and 3-way 

and signalling of any anomalies is guaranteed.

 

N.B.:

 in these conditions the boiler is still 

powered.

• 

“Off” mode.

 By holding the button (3) down 

for 8 seconds, the display switches-off and the 

boiler is off completely. The safety functions are 

not guaranteed in this mode.

 

IMPORTANT NOTE:

 in these conditions the 

boiler is considered still live even if there are 

no functions active.

• 

Display operation.

 The display lights up dur-

ing the use of the control panel or if the burner 

is ignited, after 15 seconds of inactivity, the 

brightness drops until only the active symbols 

are displayed. The lighting mode can be varied 

via parameter P2 in the P.C.B. programming 

menu.

Содержание 3.020928

Страница 1: ...MAIOR EOLO X 28 Instruction and recommendation booklet 1 038769ENG...

Страница 2: ......

Страница 3: ...specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits esta...

Страница 4: ...ce 19 2 2 General warnings 19 2 3 Control panel 19 2 4 Using the boiler 20 2 5 Troubleshooting 21 2 6 Boiler shutdown 22 2 7 Restoring central heating system pressure 22 2 8 System draining 22 2 9 Ant...

Страница 5: ...ances underneath the boiler as they could be damaged if the safety valve intervenes if the drain trap is blocked or if there are leaks from the hydraulic connec tions otherwise the manufacturer cannot...

Страница 6: ...ts the central heating circuit from freez ing by introducing a top quality anti freeze liquid into this circuit which is not noxious to health The instructions of the manufacturer of this liquid must...

Страница 7: ...cal standards in force in order to protect the system and the appliance from deposits e g scale slurry or other hazardous deposits Water connections must be made in a rational way using the couplings...

Страница 8: ...h its climate thermostat function disabled i e it must be set to On Off mode Comando Amico Remoto Remote Control V2 or On Off chrono thermostat electrical con nections Optional The operations describe...

Страница 9: ...haust in individual flue or to the outside The boiler with this type of configuration is classified as type B22 in accordance with the technical standards in force With this configuration air intake t...

Страница 10: ...with the boiler as standard DIAPHRAGM Shutter regulation table Flue gas shutter notch Type of installation duct length in metres 2 4 7 10 60 100 horizontal concentric kit From 0 to 0 5 From 0 5 to 1...

Страница 11: ...6 Exhaust m 2 0 Terminal complete with concentric vertical intake exhaust 80 125 Intake and Exhaust 33 m 2 0 m 5 5 Intake m 14 3 Exhaust m 11 0 Concentric vertical intake exhaust termi nal 80 125 Inta...

Страница 12: ...it 80 125 Kit assembly Fig 1 18 install the bend with flange 2 onto the central hole of the boiler inserting the gasket 1 and tighten using the screws in cluded in the kit Fit the male end smooth of t...

Страница 13: ...in the figure Combustion products are expelled from pipe S Air is taken in through pipe A for combustion The intake pipe A can be installed either on the right or left hand side of the central exhaust...

Страница 14: ...screws included in the kit Remove the flat flange present in the lateral hole with respect to the central one ac cording to needs and replace it with the flange 3 positioning the gasket 2 already pre...

Страница 15: ...gas exhaust outlets to the same height Temperature loss in insulated flue ducting To prevent problems of flue gas condensate in the insulated exhaust pipe 80 due to flue gas cooling through the wall t...

Страница 16: ...edatlowspeedtoensurerelease of air bubbles in the water via the boiler and heating system vents The boiler has a built in automatic venting valve on the circulator Check if the cap is loose Open the r...

Страница 17: ...n type B it is compulsory to mount the appropriate top protection cover along with the flue exhaust kit Anti freeze kit with resistance on request If the boiler is installed in a place where the tempe...

Страница 18: ...itive signal pressure point 8 Negative signal pressure point 9 Flue pressure switch 10 Flow probe 11 Fumes hood 12 Safety thermostat 13 Primary heat exchanger 14 Ignition and detection electrodes 15 S...

Страница 19: ...cal power requires some funda mental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the appli ance...

Страница 20: ...to the boiler being powered without presence of flame Each time the burner ignites the relative flame present symbol is displayed 11 with relative output scale Operation with Comando Amico RemotoV2 C...

Страница 21: ...nables fan start up incorrectly or in the event of a flue gas pressure switch fault If normal conditions are restored the boiler restarts without having to be reset 1 12 Storage tank probe anomaly If...

Страница 22: ...y of the appliance and the domestic hot water heating system in areas where the temperature falls below zero we recommend protecting the central heating system with anti freeze liquid and installing t...

Страница 23: ...and that the manometer indicates a pressure of 1 1 2 bar make sure the air valve cap is open and that the system is well deaerated switch the boiler on and check correct ignition make sure the gas ma...

Страница 24: ...minating resistance R8 The connector X5 is used for the connection to the relay board The connector X6 is for connection to a personal computer The connector X8 is used for software updating operation...

Страница 25: ...he type of gas being used S3 Boiler type Establishes the boiler type and its functioning mode 0 combi 1 24 kW storage tank 2 28 kW storage tank 3 32kW storage tank 0 3 2 S4 Power block Establishes the...

Страница 26: ...0 P5 Relay 3 optional The boiler is set up for functioning with the relay P C B optional which can be configured 0 Off 1 Chiller remote activation 2 General alarm 3 CH phase active 4 External gas val...

Страница 27: ...be adjusted must not be lower than that stated in the tables par 3 18 Adjustment any of the boiler maximum heat output in central heating phase To adjust the maximum heat output during the heating ph...

Страница 28: ...tion of approx 10 seconds N B during self check the boiler remains off including signalling 3 15 SOLAR PANELS COUPLING FUNCTION In the event of integration of DHW heating with solar panel systems for...

Страница 29: ...the guard a 3 Unhook the decorative frame c from the relative lower retainers 4 Remove the decorative frame c from the cas ing e 5 Loosen the 2 front screws d that fasten the casing 6 Loosen the 2 lo...

Страница 30: ...30 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN...

Страница 31: ...7 22 0 18920 2 49 7 43 75 8 1 86 18 61 189 8 1 83 22 76 232 1 21 0 18060 2 38 6 82 69 6 1 78 17 24 175 8 1 75 20 92 213 4 20 0 17200 2 27 6 24 63 7 1 70 15 91 162 3 1 67 19 18 195 6 19 0 16340 2 17 5...

Страница 32: ...eat output useful kW kcal h 11 2 9632 Efficiency at nominal heat output 94 3 Efficiency at 30 nominal heat output load 91 5 Heat loss at case with burner On Off 0 0 0 53 Heat loss at flue with burner...

Страница 33: ...odel code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH m...

Страница 34: ......

Страница 35: ......

Страница 36: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Отзывы: