10
MIX 750
Dear customer,
congratulations on your choice of purchase: the IMER cement
mixer, the result of years of experience, is a very reliable machine
equipped with all the latest technical innovations.
The machine can mix both dry or wet fine grain materials (plaster,
mortar, cement, floor sub-bases, rendering, synthetic resins or
pre-packed mixes).
WORKING IN SAFETY
In order to be able to work in complete safety, the following
instructions must be read carefully
- This OPERATING AND MAINTENANCE manual must be kept
on site by the person responsible for the site, e.g. the SITE
FOREMAN, and must always be available for consultation.
- The manual should be considered as being an integral part of the
machine, and must be kept for futur
e reference
until
the machine itself is disposed of. If the manual becomes damaged
or lost, a replacement can be obtained from the manufacturer.
- The manual contains important information regarding the
preparation of the site, installation and use of the machine,
maintenance and spare parts ordering. Nevertheless, the installer
and operator must both have adequate experience and knowledge
of the machine.
- In order that the safety of the operator, safe working and long life
of the equipment can all be guaranteed, the instructions in this
manual must be followed together with safety standards and health
and safety at work laws currently in force (use of suitable footwear
and clothing, use of helmets, gloves and goggles, etc. in
accordance with S.I N° 3073 of 30/11/92.
ALWAYS MAKE SURE THAT SIGNS ARE LEGIBLE
It is strictly forbidden to carry out any form of
modification to the structure or working parts of the machine.
IMER International decline any responsibility in the case of non-
compliance with laws and standards governing the use of this
equipment. In particular: improper use, defective power supply,
lack of maintenance, unauthorised modifications, partial or total
failure to observe instructions contained in this manual.
1. DESIGN STANDARDS
The MIX750 mixer has been designed and constructed in
accordance with the following standards
.
2. SOUND PRESSURE LEVEL AND VIBRATIONS
Table 2 shows the sound pressure level measured loadless at
the operator s ear (LPA) and of the vibrations transmitted during
operation.
3. MIXING CAPACITY
The mixing capacity of the machine per cycle is 480 litres
(approximately half of the tank height).
4. SAFETY MEASURES
-The IMER cement mixer can only function if all the safety devices
with which it is equipped are in perfect condition.
-The machine will not operate if the mains connection is defective.
-On-site power connection lines must be installed so that they
cannot be damaged. Do not stand the machine on the mains
connection line.
-The power lines must be installed so that water cannot penetrate
connections. Only use connectors fitted with protection against
water spray.
-Repairs to the electrical plant must only be carried out by
specialised personnel. Do not operate the mixer during
maintenance or repair operations.
-Accident prevention and health and safety at work regulations
must be complied with in the working area.
The machine must only be stopped using the
appropriate switch.
Do not open the tank protection cover to stop the
machine.
5. ELECTRICAL SAFETY
The IMER mixer complies with standards EN60204-1. In
particular, it is equipped with a system that prevents automatic
restart after the power supply line is interrupted.
-Residual current protection of electrical equipment
-Electrical safety device that prevents the machine from operating
when the tank protection cover is open.
When used on construction sites, the mixer can be connected to
an earthing system by attaching an earthing braid (or wire) of
minimum section 16 mm² (see Fig. 2).
6. MECHANICAL SAFETY
-A guard over the outlet prevents access to the mixing zone.
-The tank protection cover allows the mix components to be loaded
without access to the mixing zone.
The mixer will stop if the cover is opened.
7. TRANSPORT
WARNING!! Always disconnect the machine from the
mains before moving it.
-When on-site, the mixer can be moved manually from one location
to another as shown in Fig. 3.
-For other types of handling, the mixer must be lifted using a four-
cable sling attached to the lifting lugs, as shown in Fig. 4.
8. INSTALLATION
Lift the mixer (the mixer is fitted with a lifting jack - ref. 4, fig. 7).
- Screw in the outlet opening handle (see Fig. 6).
If there are no lifting means available, lift the mixer using the jack
supplied (see Fig. 7).
1 - Raise the rear supporting legs (Ref. 2 Fig. 7) to their maximum
height and lock them in position using the locking pins.
2 - Use the handle (Ref. 1 Fig. 7) to raise the machine, resting it
on the rear legs (Ref. 2 Fig. 7).
3 - Position the front legs (Ref. 3 Fig. 7) (towing side) at the height
required and lock them using the locking pins.
4 - If the machine is to be positioned at maximum height, insert
the lower lug (Ref. 5 Fig. 7) in the support (Ref. 7 Fig. 7), raise and
lock the rear legs (Ref. 2 Fig. 7) at the third hole from the bottom.
5 - Remove the lower fork connection Ref. 5 and lower the jack so
that the upper fork connection can be inserted (Ref. 6 Fig. 7),
then complete the lifting operation.
For intermediate working levels, the rear part of the machine should
be lifted in a single operation, as in points 1 and 2, by using the
lower connection point on the jack (Ref. 5 Fig. 7).
To return the machine to the towing position, follow this procedure
in reverse order.
Position the machine on level ground, adjusting the telescopic
legs to the required height.
Ensure that the machine is in a stable working position.
9. USE
-Do not allow other people to remain in the vicinity of the machine
during operation.
-Do not use the machine in a fire-risk zone. Sparks may cause
fires or explosions.
-Always switch off the machine before leaving it unattended.
-The machine must only be transported or positioned with the
motor switched off.
9.1 START-UP
9.1.1 ELECTRICAL CONNECTION
-Check that the supply voltage is the same as dataplate
specifications.
-Ensure that the power supply line is fitted with a differential
protection device upstream.
-Connect the machine to the earthing plant and the mains power
supply.
-Ensure that the blades rotate in a clockwise direction.
If the paddles rotate in an anti-clockwise direction, stop the
machine, disconnect the mains plug and invert one of the phases
inside the plug, by rotating the inverter slot between the pins using
a screwdriver (Fig. 8).
- Start the motor by pressing the black on/off pushbutton on the
control panel.
9.1.2 ENDOTHERMIC MOTOR
-Check the motor (see motor manual).
-Check the motor oil level (see motor manual).
-Fill the fuel tank (see motor manual).
T A B L E 2
T Y P E O F M O T O R
L
p A
A e q
E L E C T R IC
7 0 d B
-
E N G IN E H O N D A
8 8 d B
-
Содержание 1194636