G P I B C O M M A N D R E F E R E N C E
GPIB Command Reference
01_10
FPM-8200
61
C H A P T E R
4
Action
Requests the calibrated detector responsivity for the currently selected wavelength.
Response
GPIB standard <nrf value>, in units: mA / mW
Note
The information should correspond with that on your latest ILX Lightwave calibration certificate for
this meter. If not, contact ILX Lightwave Customer Service to resolve the discrepancy.
This information can be useful for understanding the characteristics of your FPM−8200 meter. Notice
for example that detector current is much less at shorter wavelengths.
For more information, see the discussion of the calibration certificate at the end of Chapter Two.
Examples
RESP?˙Response 1.193E−2 means the detector produces 0.01193 mA/mW at the currently set
wavelength.
Action
Performs the following:
*RCL 0 (see above)
Sets OCIS state
Sets OQIS state
Notes
OCIS = Operation−complete Command Idle State. This is the same FPM−8200 state as after *OPC:
no further operations to complete.
OQIS = Operation−complete Query Idle State. This is the same FPM−8200 state as after *OPC?: no
further operations to complete.
These idle states allow the FPM−8200 to complete its reset process (no operations pending) before
continuing with other operations.
Example
*RST
Action
Saves the current setup configuration in FPM 8200 memory.
Value range
1 through 10
Notes
Configuration 0 is reserved for a factory−set default configuration. See *RCL.
Same function as SAVE on the front panel. See Chapter Two. See *RCL, or the discussion of Save
and Recall in Chapter Two, for a list of the configuration functions saved.
It is normally not necessary to save the current setup for next power−ON. The current setup is
automatically stored for recall at next power−ON unless you use *PSC to tell the FPM−8200 not to do
so.
Example
*SAV 2
—
Save the current setup configuration as #2.
RESP?
Responsivity?
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
*RST
Reset
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
*SAV <nrf value>
Save
C
OMMON
D
EVICE
D
EPENDENT
F
RONT
P
ANEL
Содержание FPM-8200
Страница 2: ......
Страница 8: ...L I S T O F FIG U R E S vi FPM 8200...
Страница 10: ...L I S T O F TA B L E S viii FPM 8200...
Страница 16: ...WA R R A N T Y xiv FPM 8200...
Страница 36: ...FR O NT PA N E L O P E R A T I O N Operating Guidelines 20 FPM 8200 C H A P T E R 2...
Страница 90: ...TR O U B L E S H OO T I N G A N D M A I N T E N A N C E Error Messages 74 FPM 8200 C H A P T E R 5...
Страница 96: ...80 FPM 8200 A P P E N D I X A...