Glossary of Terms
444
CiA DS 403
DS =
D
raft
S
tandard
CAN device profile for HMI
CiA DS 404
DS =
D
raft
S
tandard
CAN device profile for measurement and
control technology
CiA DS 405
DS =
D
raft
S
tandard
Specification for interface to programmable
controllers (IEC 61131-3)
CiA DS 406
DS =
D
raft
S
tandard
CAN device profile for encoders
CiA DS 407
DS =
D
raft
S
tandard
CAN application profile for local public
transport
Clamp 15
In vehicles clamp 15 is the plus cable switched
by the ignition lock.
COB-ID
COB =
C
ommunication
Ob
ject
ID =
Id
entifier
Via the COB-ID the participants distinguish the
different messages to be exchanged.
CoDeSys
CoDeSys
®
is a registered trademark of 3S –
Smart Software Solutions GmbH, Germany.
"CoDeSys for Automation Alliance" associates
companies of the automation industry whose
hardware devices are all programmed with the
widely used IEC 61131-3 development tool
CoDeSys
®
.
Homepage
CRC
CRC =
C
yclic
R
edundancy
C
heck
CRC is a method of information technology to
determine a test value for data, to detect faults
during the transmission or duplication of data.
Prior to the transmission of a block of data, a
CRC value is calculated. After the end of the
transaction the CRC value is calculated again
at the target location. Then, these two test
values are compared.
Cycle time
This is the time for a cycle. The PLC program
performs one complete run.
Depending on event-controlled branchings in
the program this can take longer or shorter.
D
DC
D
irect
C
urrent
DC
D
iagnostic
C
overage
Diagnostic coverage is the measure of the
effectiveness of diagnostics as the ratio
between the failure rate of detected dangerous
failures and the failure rate of total dangerous
failures:
Formula: DC = failure rate detected dangerous failures /
total dangerous failures
Designation
Range
none
DC < 60 %
low
60 % < DC < 90 %
medium
90 % < DC < 99 %
high
99 % < DC
Table: Diagnostic coverage DC
An accuracy of 5 % is assumed for the limit
values shown in the table.
Diagnostic coverage can be determined for the
whole safety-related system or for only parts of
the safety-related system.