PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
232
Parameters of the inputs
7748
Parameter
Data type
Description
EXECUTE BOOL
FALSE
TRUE (edge):
POU is executed once
otherwise: POU not active
A POU already started is processed.
CHANNEL
BYTE
CAN interface (1...n) depending on the device
ACTIVE
BOOL
TRUE:
DTC is active
Cyclically transmitted (1x per second) as DM1
FALSE:
DTC is no longer active
Saved in the hardware configuration
Transmitted as DM2 when requested
REDSTOPLAMP
BOOL
red stop lamp
TRUE: OFF
FALSE: ON
AMBERWARNINGLAMP
BOOL
Amber warning lamp
TRUE: OUT
FALSE: ON
PROTECTLAMP BOOL
protect
lamp
TRUE: OFF
FALSE: ON
SPN WORD
S
uspect
P
arameter
N
umber
FMI BYTE
F
ailure
M
ode
I
ndicator
permissible values = 00...1F
16
= 0...31
10
SPN_CM BOOL
conversion
method
preset = FALSE
Parameters of the outputs
7750
Parameter
Data type
Description
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
data was marked "active" in the error memory
242
F2
Error: setting is not possible