Summary of Contents for 1517130000

Page 1: ...Logic Unit WCU 501 WCU 650 Manual Let s connect...

Page 2: ...talling the software 7 5 2 Connecting the PC 7 5 3 Starting the program 8 6 Configuration 9 6 1 Creating a project 9 6 2 Operating the programming interface 9 6 3 Function block library 10 6 4 Simulat...

Page 3: ...ow the in structions given in this manual CAUTION Risk of injury Notes with the signal word Caution warn you of situations which may result in injury if you do not follow the instructions given in thi...

Page 4: ...aws provisions and standards Follow these instructions and keep the docu mentation so it is accessible to all users at all times 2 2 Intended use The logic units in the WCU range are compact controlle...

Page 5: ...rating system Windows 7 or higher using the corre sponding adapter WCU 501 logic unit WCU 650 logic unit Overview of WCU 650 connections Colour Connection Function Red VDD Power supply Black GND Yello...

Page 6: ...ted can have a cross section of 0 25 to 1 5 mm We recommend using wire end ferrules in order to make secure connections Make the connections as shown in the pin assignment see printing on the logic un...

Page 7: ...M_miConL appears Install the miCon L software from the WM_miCon L folder by running miCon L_WM_DE_V3 6 exe IMPORTANT select C miCon L as the target directory and follow the instructions in the soft wa...

Page 8: ...dow The serial interfaces avail able are displayed Settings window Select your interface and confirm by pressing OK You can work out which is the interface to the logic unit by disconnecting the USB c...

Page 9: ...ing interface The programming interface is split into four areas 1 2 3 4 Working environment for miCon L software 1 Program tree 2 Programming interface 3 Current selection 4 Selection area libraries...

Page 10: ...lock 2 1 2 Connecting function blocks The connection between the function blocks is displayed Function blocks connected 6 3 Function block library In order to receive information on a function block i...

Page 11: ...Simulation icon The simulation window opens Simulation window If you have not yet done so open up the MAIN tree Open the program tree If you have not yet done so open PROGRAM by dou ble clicking on it...

Page 12: ...a new or changed program to the logic unit proceed as follows Connect the logic unit to the power supply Connect the logic unit to the PC using the USB cable Click on the Download icon Start download...

Page 13: ...MAIN tree If you have not yet done so double click on PROGRAM to open it The miCon L window opens if there is no program on the logic unit yet or the program is not the same as yours miCon L window T...

Page 14: ...LED should light up The ventilation unit Output 1 OUT 1 is switched on using another switch Input 2 Switch 2 IN 2 if the tem perature sensor Input 3 IN 3 generates a signal greater than 5 V If the te...

Page 15: ...arity protection Yes combined with external fuse Analogue inputs Number 3 6 Pin assignment IN 3 IN 4 IN 5 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 Resolution 10 bit 12 bit Input voltage 0 30 V DC Input resistanc...

Page 16: ...ment OUT 5 OUT 9 Output voltage GND 0 25 V Output current per channel 1 A Switching frequency 1 5 kHz 1 10 kHz CAN interface Baud rate 100 125 250 500 kbit Bus system ISO 11898 2 CAN 2 0B CAN 2 0A Ide...

Page 17: ...501 STARTER KIT WCU 501 logic unit with RS232 cable and RS232 USB converter 2515030000 WCU 501 RS232 CABLE RS232 cable for WCU 501 without RS232 USB converter 2010680000 LOGIC UNIT WCU 650 Graphicall...

Page 18: ...technological challenges of tomorrow We are therefore continuously developing innovative sustainable and useful solutions for their individual needs Together we set standards in Industrial Connectivit...

Reviews: