Visualisations in the device
Operate camera(s) on the PDM
132
Use the Ethernet camera image in CoDeSys
9585
Applies only to the following devices:
- PDM360NG: CR1080, CR1081, CR1082, CR9042
NOTE
►
Switch off cameras in the visualisation BEFORE an image change is started. Otherwise, the old
camera image stays visible in the new image.
►
Do not switch on the requested cameras until the new visualisation is displayed.
Only the visible area of the display (800 x 480 pixels) can be used for the camera image. Positions
outside this area (in the non-visible area) are ignored. Instead the image is represented at the last valid
position. If there was no valid position, NO image is represented.
Indicate the failure of an Ethernet camera
9586
►
Indicate a Boolean type variable, e.g. PLC_PRG.connect in the category [Variables] in the field
[Input disable].
This variable is not contained in the PLC configuration.
The name of the variables is freely selectable.