24
10 Parameter setting
CAUTION!
The surface of the unit may get hot if the switching outputs are
operated at maximum load.
> Risk of burns
►
Do not touch the unit
►
Use another object (e.g. a ballpoint pen) to carry out
settings on the unit.
10.1 Parameter setting in general
1
Mode/Enter Set
►
Press [Mode/Enter] until the
requested parameter is displayed.
To select parameters in the extended
menu (menu level 2):
►
Select [EF] and briefly press [Set].
2
Mode/Enter Set
►
Press and hold [Set].
> The current parameter value flashes
for 5 s.
> Value is increased* (step by step
by pressing the button once or
continuously by keeping the button
pressed).
3
Mode/Enter Set
►
Briefly press [Mode/Enter]
(= confirmation).
> The parameter is displayed again;
the new parameter value becomes
effective.
4
Change more parameters:
►
Start again with step 1.
Finishing the parameter setting:
►
Wait for 30 s or press and hold
[Mode/Enter].
> The current measured value is
displayed.
►
Release [Mode/Enter],
> The parameter setting is completed.
*
)
Decrease the value: let the display move to the maximum setting value.
Then the cycle starts again at the minimum setting value.