CAN in the ecomatmobile controller
ifm CANopen library
Parameters of the function inputs
Name
Data type
Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
ERROR
BOOL
FALSE
→
TRUE (edge):
transmits the given error code
TRUE
→
FALSE (edge)
AND the fault is no longer indicated:
The message that there is no error is sent after a
delay of approx. 1 s
ERROR_CODE
WORD
The error code provides detailed information about
the detected fault. The values should be entered
according to the CANopen specification.
→
chapter Overview of the CANopen error codes
(
→
page
)
ERROR_REGISTER
BYTE
This object reflects the general error state of the
CANopen network participant. The values should be
entered according to the CANopen specification.
MANUFACTURER_ERROR_FIELD ARRAY [0...4] OF
BYTE
Here, up to 5 bytes of application-specific error
information can be entered. The format can be
freely selected.