70
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
CAN in the ecomatmobile controller
Description of the CAN functions
8.6.7
Function CAN2
(can only be used for devices with a 2nd CAN interface)
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
ClassicController: CR0020, CR0505
•
ExtendedController:
CR0200
•
SafetyController: CR7020, CR7021, CR7200, CR7201, CR7505, CR7506
•
SmartController:
CR2500
Function symbol:
CAN2
ENABLE
START
EXTENDED_MODE
BAUDRATE
Description
The function CAN2 initialises the 2nd CAN interface.
The function must be called if the 2nd CAN interface is to be used.
A change of the baud rate will become effective after voltage OFF/ON. The baud rates of CAN 1 and
CAN 2 can be set differently.
The input START is only set for one cycle during reboot or restart of the interface.
For the 2nd CAN interface the function libraries for SAE J1939 (
→
page
), among others, are
available.
NOTE
The function must be executed
before
the functions CAN2_... .