SmartController (CR2500) V05
CAN in the ecomatmobile controller
Use of the CAN interfaces to SAE J1939
157
Parameters of the function inputs
Name
Data type Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
PRIO BYTE
Priority
(0...7)
DA
BYTE
Logical address (target address) of the called device
PG
BYTE
Page address (normally = 0)
PF BYTE
PDU
Format
Byte
PS
BYTE
PDU Specific Byte
DST DWORD
Target
address
of the array in which the received data is
stored
Parameters of the function outputs
Name
Data type Description
RESULT
BYTE
0 = Not active
1 = Data transmission completed
2 = Function active (data transmission)
3 = Error, data cannot be sent
LEN
WORD
Number of data bytes received