274
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
Annex
System flags
12.2 System
flags
(
→
chapter Error codes and diagnostic information,
→
)
System flag
Type
Function
CANx_BAUDRATE WORD
CAN
interface x: Currently set baud rate
CANx_BUSOFF BOOL
CAN
interface
x: Interface is not on the bus
CANx_LASTERROR ¹)
BYTE
CAN interface x: Error number of the last CAN
transmission:
0= no error
≠
0
→
CAN specification
→
LEC
CANx_WARNING BOOL
CAN
interface
x: Warning threshold reached (> 96)
DOWNLOADID
WORD
Currently set download identifier
ERROR
BOOL
Set ERROR bit
ERROR_BREAK_Qx
BYTE
Wire break error on output group x
ERROR_IO
BOOL
I/O error (group bit)
ERROR_Ix
BYTE
Peripheral error on input group x
ERROR_MEMORY BOOL Memory
error
ERROR_POWER BOOL
Undervoltage/overvoltage
error
ERROR_SHORT_Qx
BYTE
Short circuit error on output group x
ERROR_VBBR
BOOL
Supply voltage error VBB
R
LED_MODE WORD
Flashing
frequency from the data structure
"LED_MODES"
SERIAL_MODE
BOOL
Switch-on of serial communication
SERIALBAUDRATE WORD
Baud
rate of the RS-232 interface
SUPPLY_VOLTAGE WORD
Supply
voltage
TEST
BOOL
Enabling the programming mode
CANx stands for the number of the CAN interface (CAN 1...x, depending on the device).
Ix/Qx stands for the input/output group (word 0...x, depending on the device).
¹) Access to this flags requires detailed knowledge of the CAN controller and is normally not required.
NOTE
Only symbol names should be used for the programming since the corresponding flag addresses can
change in case of an extension of the PLC configuration.